Related Experiment Video
Updated: Jan 28, 2026

Functional Imaging of Auditory Cortex in Adult Cats using High-field fMRI
Published on: February 19, 2014
Establishment of a Tm-shift Method for Detection of Cat-Derived Hookworms
Yeqi Fu1, Yunqiu Liu1, Asmaa M I Abuzeid1
1Guangdong Provincial Zoonosis Prevention and Control Key Laboratory, College of Veterinary Medicine, South China Agricultural University, Guangzhou 510542, P. R. China.
Abstract:
Melting temperature shift (Tm-shift) is a new detection method that analyze the melting curve on real-time PCR thermocycler using SYBR Green I fluorescent dye. To establish a Tm-shift method for the detection of Ancylostoma ceylanicum and A. tubaeforme in cats, specific primers, with GC tail of unequal length attached to their 5 ́ end, were designed based on 2 SNP loci (ITS101 and ITS296) of the internal transcribed spacer 1 (ITS1) sequences. The standard curve of Tm-shift was established using the standard plasmids of A. ceylanicum (AceP) and A. tubaeforme (AtuP). The Tm-shift method stability, sensitivity, and accuracy were tested with reference to the standard curve, and clinical fecal samples were also examined. The results demonstrated that the 2 sets of primers based on the 2 SNPs could accurately distinguish between A. ceylanicum and A. tubaeforme. The coefficient of variation (CV) of Tm-values of AceP and AtuP was 0.07% and 0.06% in ITS101 and was 0.06% and 0.08% in ITS296, respectively. The minimum detectable DNA concentration was 5.22×10-6 and 5.28×10-6 ng/μl samples of AceP and AtuP, respectively. The accuracy of Tm-shift method reached 100% based on examination of 10 hookworm DNA samples with known species. In the clinical detection of hookworm in 69 stray cat fecal sample, the Tm-shift detection results were consistent with the microscopic examination and successfully differentiated between the 2-hookworm species. In conclusion, the developed method is a rapid, sensitive and accurate technique and can provide a promising tool for clinical detection and epidemiological investigation of cat-derived hookworms.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Clinically Relevant Drug Product Specifications: Methods of Establishment
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...

