Background:
The needs for human epidermal growth factor receptor 2 (HER-2) and/or programmed death-ligand 1 (PD-L1) evaluations in gastric cancer are dramatically increasing. Although the importance of standardization of sample fixation has been widely recognized, most of the evidence regarding the fixation duration or type of fixing solution are based on breast cancer.
Aim:
To investigate the real effects of fixation conditions on HER-2 testing or PD-L1 testing for gastric cancer using gastrectomy specimens.
Methods:
Thirty-two patients who underwent gastrectomy for gastric cancer were enrolled. Their resected specimens were each divided into four pieces and fixed in four strictly controlled different durations (6 h, 24 h, and 48 h, and 1 wk) by 10% formalin (n = 22) or 10% neutral buffered formalin (NBF) (n = 10). Immunohistochemistry (IHC) of HER-2 and PD-1 was performed, and a pathology examination was conducted. In the HER-2-immunoreactive cases, all four specimens were subjected to dual-color in situ hybridization (DISH). Five cases were assessed as HER-2-positive by IHC and DISH. We used the cut-off values of 1%, 10%, and 50% to assess the IHC findings of PD-L1.
Results:
No significant difference was observed in comparisons between the shorter fixation period groups (6 h, 24 h, and 48 h) and the prolonged fixation period (1 wk) group in the HER-2 and PD-L1 analyses. Although no significant difference was observed between 10% formalin and 10% NBF within 1 wk of fixation, the superiority of 10% NBF was confirmed in a long-term (> 3 mo) fixation in both the HER-2 and PD-L1 analyses.
Conclusion:
In this small-numbered pilot study, prolonged fixation within 1 wk showed no inferiority in HER-2 or PD-L1 testing. However, a large-numbered prospective study is needed to obtain conclusive results.
More Related Videos
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Carbon-dioxide Fixation
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Pilot and Numeric Relaying
Gastric Motility
Peristaltic Waves and Chyme Formation
Upon food entry, the stomach initiates...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...