Abstract:
Percutaneous coronary intervention (PCI) is the prevalent treatment for coronary artery disease, with hundreds of thousands of stents implanted annually. Computational studies have demonstrated the role of biomechanics in the failure of vascular stents, but clinical studies is this area are limited by a lack of understanding of the deployed stent geometry, which is required to accurately model and predict the stent-induced in vivo biomechanical environment. Herein, we present an automated method to reconstruct the 3-D deployed stent configuration through the fusion of optical coherence tomography (OCT) and micro-computed tomography ( μ CT) imaging data. In an experimental setup, OCT and μ CT data were collected in stents deployed in arterial phantoms ( n=4 ). A constrained iterative deformation process directed by diffeomorphic metric mapping was developed to deform μ CT data of a stent wireframe to the OCT-derived sparse point cloud of the deployed stent. Reconstructions of the deployed stents showed excellent agreement with the ground-truth configurations, with the distance between corresponding points on the reconstructed and ground-truth configurations of [Formula: see text]. Finally, reconstructions required <30 min of computational time. In conclusion, the developed and validated reconstruction algorithm provides a complete spatially resolved reconstruction of a deployed vascular stent from commercially available imaging modalities and has the potential, with further development, to provide more accurate computational models to evaluate the in vivo post-stent mechanical environment, as well as clinical visualization of the 3-D stent geometry immediately following PCI.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Coordination Number and Geometry
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...