Related Experiment Video
Updated: Jan 28, 2026

Application of Passive Head Motion to Generate Defined Accelerations at the Heads of Rodents
Published on: July 21, 2022
Implementation and Evaluation of a 50 kHz, 28μs Motion-to-Pose Latency Head Tracking Instrument
Abstract:
This paper presents the implementation and evaluation of a 50,000-pose-sample-per-second, 6-degree-of-freedom optical head tracking instrument with motion-to-pose latency of 28μs and dynamic precision of 1-2 arcminutes. The instrument uses high-intensity infrared emitters and two duo-lateral photodiode-based optical sensors to triangulate pose. This instrument serves two purposes: it is the first step towards the requisite head tracking component in sub- 100μs motion-to-photon latency optical see-through augmented reality (OST AR) head-mounted display (HMD) systems; and it enables new avenues of research into human visual perception - including measuring the thresholds for perceptible real-virtual displacement during head rotation and other human research requiring high-sample-rate motion tracking. The instrument's tracking volume is limited to about 120×120×250 but allows for the full range of natural head rotation and is sufficient for research involving seated users. We discuss how the instrument's tracking volume is scalable in multiple ways and some of the trade-offs involved therein. Finally, we introduce a novel laser-pointer-based measurement technique for assessing the instrument's tracking latency and repeatability. We show that the instrument's motion-to-pose latency is 28μs and that it is repeatable within 1-2 arcminutes at mean rotational velocities (yaw) in excess of 500°/sec.
More Related Videos
07:09Gaze in Action: Head-mounted Eye Tracking of Children's Dynamic Visual Attention During Naturalistic Behavior
Published on: November 14, 2018
08:27Three-Dimensional Finger Motion Tracking during Needling: A Solution for the Kinematic Analysis of Acupuncture Manipulation
Published on: October 28, 2021
Related Concept Videos
Psychosexual Stages of Personality: Latency
The latency period is not...
Instrument Transformers
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Uncertainty in Measurement: Reading Instruments
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.