Related Experiment Video
Updated: Jan 28, 2026

Preparation of Silicon Nanowire Field-effect Transistor for Chemical and Biosensing Applications
Published on: April 21, 2016
Selective PQQPFPQQ Gluten Epitope Chemical Sensor with a Molecularly Imprinted Polymer Recognition Unit and an
Zofia Iskierko1, Piyush S Sharma2, Krzysztof R Noworyta2
1Department of Biotechnology , University of Verona , Strada Le Grazie 15 , 37134 Verona , Italy.
Abstract:
A molecularly imprinted polymer (MIP) recognition system was devised for selective determination of an immunogenic gluten octamer epitope, PQQPFPQQ. For that, a thin MIP film was devised, guided by density functional theory calculations, and then synthesized to become the chemosensor recognition unit. Bis(bithiophene)-based cross-linking and functional monomers were used for this synthesis. An extended-gate field-effect transistor (EG-FET) was used as the transduction unit. The EG-FET gate surface was coated with the PQQPFPQQ-templated MIP film, by electropolymerization, to result in a complete chemosensor. X-ray photoelectron spectroscopy analysis confirmed the presence of the PQQPFPQQ epitope, and its removal from the MIP film. The chemosensor selectively discriminated between the octamer analyte and another peptide of the same number of amino acids but with two of them mismatched (PQQQFPPQ). The chemosensor was validated with respect to both the PQQPFPQQ analyte and a real gluten extract from semolina flour. It was capable to determine PQQPFPQQ in the concentration range of 0.5-45 ppm with the limit of detection (LOD) = 0.11 ppm. Moreover, it was capable of determining gluten in real samples in the concentration range of 4-25 ppm with LOD = 4 ppm, which is a value sufficient for discriminating between gluten-free and non-gluten-free food products. The gluten content in semolina flour determined with the chemosensor well correlated with that determined with a commercial ELISA gluten kit. The Langmuir, Freundlich, and Langmuir-Freundlich isotherms were fitted to the epitope sorption data. The sorption parameters determined from these isotherms indicated that the imprinted cavities were quite homogeneous and that the epitope analyte was chemisorbed in them.
More Related Videos
Related Concept Videos
Measurement: Standard Units
Measurement: Derived Units
Field Effect Transistor
Motor Units
Motor Units
Motor units come in different sizes, with smaller units...
Units of Measurement
There are various well-known historical measurement systems, such as the Babylonian system, the Roman system, the Egyptian system, the Olympian system, the British system, and the Indus...

