Related Experiment Video
Updated: Jan 28, 2026

Field Postmortem Rabies Rapid Immunochromatographic Diagnostic Test for Resource-Limited Settings with Further Molecular Applications
Published on: June 29, 2020
Immunochromatographic fluorometric determination of clenbuterol with enhanced sensitivity
Yuyang Zeng1, Demei Liang1, Pimiao Zheng1
1Beijing Advanced Innovation Center for Food Nutrition and Human Health, College of Veterinary Medicine, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, Beijing Laboratory for Food Quality and Safety, China Agricultural University, 100193, Beijing, People's Republic of China.
Abstract:
A method is described to enhance the sensitivity of an immunochromatographic assay for clenbuterol (CLE) by making use of dually-labeled gold nanoparticles (GNPs), background fluorescence blocking, and immunomagnetic separation. The GNPs were labeled with biotinylated antibody and streptavidin, respectively, and dually labeled GNPs were obtained via the biotin-streptavidin interaction to amplify the detection signal. The fluorescent signal was blocked by dually labeled GNPs and decreased as the dually labeled GNPs aggregation increases on nitrocellulose membrane, which derived from fluorescent polyvinylchloride card. However, fluorescence (measured at excitation/emission wavelengths of 518/580 nm) recovers when CLE reacts with dually labeled GNPs. Immunomagnetic separation was first applied for sample pretreatment. This can offset the matrix effect and improves the sensitivity and accuracy of the assay. Under the optimal conditions, the limits of detection of CLE visually were 0.25 μg·L-1. In addition, clenbuterol can be quantified in swine urine with a 0.03 μg·L-1 detection limit. This is 60-fold lower than current immunochromatography. Response is linear in the 0.06-0.59 μg·L-1 concentration range, and the recoveries from spiked swine urine range from 81 to 115%." Graphical abstract Schematic presentation of the strategies for improving sensitivity of immunochromatographic assay. It includes immunomagnetic separations, dually-labeled gold nanoparticles and background fluorescence blocking. The assay was applied to detect clenbuterol (CLE) in swine urine with an excellent performance.
Related Concept Videos
Bioavailability Enhancement: Determination and Conceptual Approaches in Overcoming Bioavailability Problems
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement
Bioavailability Enhancement: Drug Stability Enhancement and GI Retention
Determining Order of Reaction