Related Experiment Video
Updated: Jan 28, 2026

Author Spotlight: Enhancement of Salient Object Detection for Smart Grid Applications
Published on: December 15, 2023
Separation of bones from soft tissue in chest radiographs: Anatomy-specific orientation-frequency-specific deep
Amin Zarshenas1, Junchi Liu1, Paul Forti1
1Medical Imaging Research Center & Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, 60616, USA.
Purpose:
Lung nodules that are missed by radiologists as well as by computer-aided detection (CAD) systems mostly overlap with ribs and clavicles. Removing the bony structures would result in better visualization of undetectable lesions. Our purpose in this study was to develop a virtual dual-energy imaging system to separate ribs and clavicles from soft tissue in chest radiographs.
Methods:
We developed a mixture of anatomy-specific, orientation-frequency-specific (ASOFS) deep neural network convolution (NNC) experts. Anatomy-specific (AS) NNC was designed to separate the bony structures from soft tissue in different lung segments. While an AS design was proposed previously under our massive-training artificial neural networks (MTANN) framework, in this work, we newly mathematically defined an AS experts model as well as its learning and inference strategies in a probabilistic deep-learning framework. In addition, in combination with our AS experts design, we newly proposed the orientation-frequency-specific (OFS) NNC models to decompose bone and soft-tissue structures into specific orientation-frequency components of different scales using a multi-resolution decomposition technique. We trained multiple NNC models, each of which is an expert for a specific orientation-frequency component in a particular anatomic segment. Perfect reconstruction discrete wavelet transform was used for OFS decomposition/reconstruction, while we introduced a soft-gating layer to merge the predictions of AS NNC experts. To train our model, we used the bone images obtained from a dual-energy system as the target (or teaching) images while the standard chest radiographs were used as the input to our model. The training, validation, and test were performed in a nested two-fold cross-validation manner.
Results:
We used a database of 118 chest radiographs with pulmonary nodules to evaluate our NNC scheme. In order to evaluate our scheme, we performed quantitative and qualitative evaluation of the predicted bone and soft-tissue images from our model as well as the ones of a state-of-the-art technique where the "gold-standard" dual-energy bone and soft-tissue images were used as the reference images. Both quantitative and qualitative evaluations demonstrated that our ASOFS NNC was superior to the state-of-the-art bone-suppression technique. Particularly, our scheme was better able to maintain the conspicuity of nodules and lung vessels, comparing to the reference technique, while it separated ribs and clavicles from soft tissue. Comparing to a state-of-the-art bone suppression technique, our bone images had substantially higher (t-test; P < 0.01) similarity, in terms of structural similarity index (SSIM) and peak signal-to-noise ratio (PSNR), to the "gold-standard" dual-energy bone images.
Conclusions:
Our deep ASOFS NNC scheme can decompose chest radiographs into their bone and soft-tissue images accurately, offering the improved conspicuity of lung nodules and vessels, and therefore would be useful for radiologists as well as CAD systems in detecting lung nodules in chest radiographs.
Related Concept Videos
Gross Anatomy of Bone
The diaphysis is the tubular shaft that runs between the proximal and distal ends of the bone. The walls of the diaphysis are composed of dense and hard compact bone made of numerous osteons — the functional unit of the compact bone. The hollow region in the diaphysis is called the medullary cavity, which harbors the bone marrow. In infants and children, this marrow cavity is filled with red marrow, whereas in...
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Density, Specific Weight, Specific Gravity and Compressibility of Fluid
Specific weight represents the weight per unit volume and is calculated by multiplying...
Cell Specific Gene Expression
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...