Related Experiment Video
Updated: Jan 28, 2026

The Innovation Arena: A Method for Comparing Innovative Problem-Solving Across Groups
Published on: May 13, 2022
Integration of five groups of POPs into one multi-analyte method for human blood serum analysis: An innovative
Andrea Svarcova1, Darina Lankova1, Tomas Gramblicka1
1University of Chemistry and Technology, Prague, Faculty of Food and Biochemical Technology, Department of Food Analysis and Nutrition, Technicka 3, 166 28 Prague, 6, Czech Republic.
Abstract:
Within this study, a new analytical strategy was developed and validated for the simultaneous determination of 78 organohalogenated contaminants in human blood serum, namely 40 flame retardants (FRs) including 7 "novel" brominated and chlorinated FRs (novel FRs), 19 perfluoroalkylated substances (PFASs), 11 organochlorine pesticides (OCPs) and 8 polychlorinated biphenyls (PCBs). The integral sample preparation procedure was implemented for the isolation of non-polar compounds, based on three-step solvent extraction using a mixture of n-hexane:diethylether (9:1, v/v), followed by purification using a solid-phase extraction (SPE) on a Florisil® column. For isolation of more polar and lipophobic analytes, the remaining fraction from the first extraction step was further processed, using a modified QuEChERS method. Depending on the polarity and volatility of target compounds, either gas chromatography coupled to (tandem) mass spectrometry (GC-MS/(MS)), or ultra-high performance liquid chromatography coupled to triple quadrupole tandem mass spectrometry (UHPLC-MS/MS), was employed for their identification/quantification. Within the subsequent pilot study, the new validated procedure was successfully applied to the monitoring of organohalogenated contaminants in 38 samples of human blood serum obtained from Prague, Czech Republic. From 78 targeted analytes, 10 PFASs, 10 OCPs, 8 PCBs and 6 BFRs were detected in serum at concentrations above method quantification limits (MQLs). In the serum samples, the amounts of determined PFASs were in the range<0.01-8.97ngmL-1 (mean 0.631ngmL-1), OCPs and PCBs ranged from <0.1-1626ngg-1 lw (mean 40.0ngg-1 lw) and<0.1-481ngg-1 lw (mean 63.3ngg-1 lw), respectively.
Related Concept Videos
Development of Analytical Methods
Blood Studies for Cardiovascular System III: Serum Lipid Profile
Serum lipids are fats and fatty substances in the blood and are crucial for various bodily functions, including energy storage, cellular structure, and hormone production. Serum lipids consist of cholesterol, triglycerides, and phospholipids.
Cholesterol is a soft, fat-like substance found in all body cells. It is crucial for producing hormones, vitamin D, and substances that aid...
Serum Laboratory Studies, Stool Test, Breath Test
Serum Studies: Renal Function Tests
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...
Velocity and Position by Integral Method
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...