Related Experiment Video
Updated: Jan 28, 2026

Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials
Published on: August 13, 2019
Experimental evaluation of cortical bone substitute materials for tool development, surgical training and drill bit
Arne Feldmann1, Marcel Schweizer2, Simon Stucki2
1Institute for Surgical Technology and Biomechanics, University of Bern, Stauffacherstrasse 78, 3014 Bern, Switzerland.
Abstract:
Surgeons, scientists and development engineers of surgical devices require phantoms and materials for testing and training purposes. Human or animal bones are the gold standard, but difficult to obtain, prepare and handle. While polyurethane foams can be used as a substitute for trabecular bone, cortical bone substitutes have not been evaluated. In this study, a standard surgical drill bit (⌀ 3.2 mm) with clinical process parameters was used to compare 5 different materials with bovine cortical bone: polyurethane with three different densities, short-fiber-filled epoxy and an artificial bone material. Drillings were repeated 100 times with 6 drill bits for each material. The results indicate that none of the substitute materials can be used without compromises. Axial drilling thrust forces in short-fiber-filled-epoxy are similar to bone. However, its hard fibers significantly deteriorate the chisel edge and flank face and increases the thrust force with each drilling (doubles within the first 10 repetitions) so that drill bits should only be used very limited times. The densest polyurethane (Renshape BM-5166) has the advantage of comparable torque values with bovine cortical bone (up to 60 repetitions). Additionally to these findings, a significant and potentially clinical relevant increase of axial drilling force (80%) and torque (56%) was found during 100 drillings in bovine cortical bone.
More Related Videos
Related Concept Videos
Diazonium Group Substitution: –OH and –H
Members Made of Elastoplastic Material
As the bending moment...
Genetic Material
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Stability of Substituted Cyclohexanes
The two chair conformations of cyclohexanes undergo rapid interconversion at room temperature. Both forms have identical energies and stabilities, each comprising equal amounts of the equilibrium mixture. Replacing a hydrogen atom with a functional group makes the two conformations energetically non-equivalent.
For example, in...
Nucleophilic Substitution Reactions
In 1896, the German chemist Paul Walden discovered that he could interconvert pure enantiomeric (+) and (-) malic acids through a series of reactions. This conversion suggested the involvement of optical inversion during the substitution reaction. Further, in 1930, Sir Christopher Ingold described for the first time two different forms of nucleophilic substitution reactions, which are known as SN1 (nucleophilic substitution unimolecular) and SN2 (nucleophilic substitution...

