Deletions and loss-of-function variants in TP63 associated with orofacial clefting

Kriti D Khandelwal1, Marie-José H van den Boogaard2, Sarah L Mehrem3,4

  • 1Department of Orthodontics and Craniofacial Biology, Radboud Institute for Molecular Life Sciences, Radboud University Medical Center, 6500 HB, Nijmegen, The Netherlands.

Related Concept Videos

Loss of Tumor Suppressor Gene Functions01:12

Loss of Tumor Suppressor Gene Functions

Tumor suppressor genes are normal genes that can slow down cell division, repair DNA mistakes, or program the cells for apoptosis in case of irreparable damage. Hence, they play an essential role in preventing the proliferation of damaged cells.
When the tumor suppressor genes develop mutations or are lost, cells start growing out of control, leading to cancer. However, a single functional copy of the tumor suppressor gene is enough for the cells to maintain their normal functions and cell...
6.0K
Histone Variants at the Centromere02:30

Histone Variants at the Centromere

Histone variants are the histone proteins with structural and sequence variations. These variants may be regarded as “mutant” forms that replace their canonical histone counterparts in the nucleosomes. Specific post-translational modifications on the histone variants enable further chromatin complexity and regulate tissue-specific gene expression. The most common histone variants are from histone H2A, H2B, and linker histone H1 families. However, several variants of histone H3...
5.0K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
541
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
384
Major Losses in Pipes01:28

Major Losses in Pipes

When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K
Minor Losses in Pipes01:25

Minor Losses in Pipes

In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
1.9K