Related Experiment Video
Updated: Jan 28, 2026

Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Correction of self-absorption effect in calibration-free laser-induced breakdown spectroscopy (CF-LIBS) with
Tianqi Li1, Zongyu Hou1, Yangting Fu1
1State Key Lab of Power System, Department of Energy and Power Engineering, Tsinghua-BP Clean Energy Centre, Tsinghua University, Beijing, 100084, China.
Abstract:
The self-absorption effect due to optically thick property greatly influences the measured line intensities as well as the performance of quantification for laser-induced breakdown spectroscopy (LIBS) especially for calibration-free LIBS which requires proper correction. In this paper, a new self-absorption correction method for Calibration-Free LIBS (CF-LIBS), called blackbody radiation referenced self-absorption correction (BRR-SAC) is proposed. An iterative algorithm was designed to calculate the plasma temperature and normally hard-to-obtain collection efficiency of the optical collection system by directly comparing the measured spectrum with the corresponding theoretical blackbody radiation for self-absorption correction. Compared with generally applied self-absorption correction methods based on the principle of curve of growth, the proposed method has obvious advantages of simpler programming, higher computation efficiency, and its independency of the availability or accuracy of line broadening coefficients. Experiments were conducted on titanium alloy samples. The experimental results showed that the self-absorption was corrected with increased linearity of the Boltzmann plots and the measurement accuracy of the elemental concentration was significantly improved through BRR-SAC. Compared with the traditional CF-LIBS with self-absorption correction, the proposed method also showed better performance. In addition, BRR-SAC provides a simple way to obtain the collection efficiency of the experimental setup, which benefits the plasma diagnostics and quantitative analysis.
More Related Videos
10:17Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Absorption of Radiation
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...