Related Experiment Video
Updated: Jan 28, 2026

Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
Published on: October 20, 2010
An innovative gynecological HDR brachytherapy applicator system for treatment delivery and real-time verification
Anna Romanyukha1, Mauro Carrara2, Davide Mazzeo3
1Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia.
Abstract:
The multichannel vaginal cylinder (MVC) applicator employed for gynecological high dose rate (HDR) brachytherapy increases dose delivery complexity, and thus makes the treatment more prone to errors. A quality assurance (QA) procedure tracking the source throughout dose delivery can detect dwell position and time errors in the multiple channels of the applicator. A new MVC system with integrated real time in vivo treatment delivery QA has been developed based on diodes embedded on the outer surface of the MVC. It has been pre-calibrated and verified using a non-clinical treatment plan with consecutive test positions and dwell times within each catheter, followed by the delivery of ten clinical plans of adjuvant vaginal cuff brachytherapy following hysterectomy for endometrial cancer. The non-clinical verification showed overall mean dwell position and time discrepancies between the nominal and measured treatment of -0.2 ± 0.5 mm and -0.1 ± 0.1 s (k = 1), respectively. The clinical plans showed mean positional discrepancies of 0.2 ± 0.4 and 0.0 ± 0.8 mm, for the central and peripheral catheters, respectively, and mean dwell time discrepancies of -0.1 ± 0.2 and -0.0 ± 0.1 s for central and peripheral catheters, respectively. The innovative prototype of the MVC system has shown the ability to track the source with sub-mm and sub-second accuracy, and demonstrated potential for its incorporation into the clinical routine.
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Strategies of Self-Presentation II: Self-Verification
Real-World Application of Classical Conditioning
Higher-order, or second-order, conditioning occurs when a neutral stimulus becomes associated with an already established conditioned stimulus through repeated pairings. For instance, if a dog has been...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Parkinson's Disease: Treatment
Parkinson's Disease is primarily a result of the loss of dopaminergic neurons in the substantia nigra pars compacta. The cornerstone of...
Alzheimer's Disease: Treatment

