Purpose:
To test three potential prosthetic material options for zirconia implants in regard to their mechanical properties, loading and retention capacity as well as to record abrasion after chewing simulation followed by thermocyclic aging.
Methods:
Molar crowns (n = 96) of three different computer-aided design/computer-aided manufacturing (CAD/CAM) materials were produced and cemented on zirconia implants (ceramic.implant, Vita) with a diameter of 4.5 mm. Monolithic zirconia (Vita YZ [YZ] with RelyX Unicem 2 Automix [RUN], polymer-infiltrated ceramic (Vita Enamic [VE]) with Vita Adiva F-Cem [VAF] and acrylate polymer (CAD Temp [CT]) with RelyX Ultimate [RUL]. Fracture load and retentive force of the crowns were measured after 24 h water storage at 37 °C and after a chewing simulation followed by thermocyclic aging. Abrasion was recorded by matching stereolithography-data of the crowns obtained before and after chewing simulation. Additionally, the mechanical properties and bonding capabilities of the crown and cement materials were assessed.
Results:
Fracture load values were significantly highest for YZ > VE = CT. Retention force values did not differ significantly between the materials. The aging procedure did not affect the fracture load values nor the retention force significantly. Abrasion depth of the crowns was lowest for YZ followed by VE and CT. On unpolished crowns, abrasion of YZ and VE tended to be higher than on polished specimens.
Conclusions:
Based on the obtained in-vitro results, all tested materials can be recommended for the use on zirconia implants, although CT is only approved for temporary crowns. The loading and retention capacity of the materials were not significantly affected by aging.
More Related Videos
08:29Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
Published on: January 7, 2019
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Restorative Care
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying...
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...
Bone as Supporting Connective Tissue
Bone Matrix
Bone, or osseous tissue, is a connective tissue that has a large amount of two different types of matrix material. The organic matrix is similar to the matrix material found in other connective tissues, including some amount of collagen and elastic fibers. This gives strength and flexibility to the tissue. The inorganic matrix consists of mineral salts— mostly calcium salts—...
Le Chatelier's Principle: Changing Concentration