Related Experiment Video
Updated: Jan 28, 2026

Studying Triple Negative Breast Cancer Using Orthotopic Breast Cancer Model
Published on: March 20, 2020
A pilot study of low-dose CT perfusion imaging (LDCTPI) technology in patients with triple-negative breast cancer
Zong-Qiong Sun1, Shu-Dong Hu1, Lin Shao1
1Department of Radiology, Affiliated Hospital of Jiangnan University, The Fourth People's Hospital of Wuxi City, Wuxi, Jiangsu, China.
Purpose:
To investigate associations between the clinicopathologic features and CT perfusion parameters of triple-negative breast cancer (TNBC) and non-TNBC using low-dose computed tomography perfusion imaging (LDCTPI), and to find potential clinical applications in the prognosis assessment of TNBC.
Materials And Methods:
A total of 60 patients with breast cancer confirmed by pathological examination were studied prospectively using LDCTPI on a 64-slice spiral CT scanner. The acquired volume data were used for calculations, mapping, and analysis by using a tumor perfusion protocol in the CT perfusion software package to measure 2 parameters namely, blood flow (BF), and permeability surface (PS) area product. Patients were grouped into TNBC (n = 27) and non-TNBC (n = 33) subtypes. Associations between these two subtypes and clinicopathologic characteristics were evaluated by both univariate and multivariate logistic regression. CT perfusion parameters values were compared for clinicopathologic characteristics using independent 2-sample t test.
Results:
TNBC displayed higher CT perfusion parameters values (BF: 57.56±10.94 vs 52.70±7.79 mL/100 g/min, p = 0.006; PS: 38.98±9.46 vs 33.39±8.07 mL/100 g/min, p = 0.001) than non-TNBC. In addition, breast cancer with poorly histologic grade or positive Ki-67 expression showed higher BF and PS values than those with well and moderately histologic grade or negative Ki-67 expression (p < 0.05). TNBC had poorer histologic grade (P = 0.032) and higher Ki-67 expression (P = 0.013) than non-TNBC.
Conclusion:
LDCTPI is a functional imaging technology from the perspective of hemodynamics with potential of clinical applications. The BF and PS values were higher in TNBC patient group than non-TNBC group. TNBC patients also have poorer clinicopathologic outcome.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Bioavailability Study Design: Single Versus Multiple Dose Studies

