Related Experiment Video
Updated: Jan 28, 2026

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Evaluation of a Volumetric Dried Blood Spot Card Using a Gravimetric Method and a Bioanalytical Method with Capillary
Gabriel Lenk1, Shahid Ullah2, Göran Stemme1
1KTH Royal Institute of Technology Stockholm , Department of Micro and Nanosystems , 10044 Stockholm , Sweden.
Abstract:
Dried blood spot (DBS) sampling is a promising method for collection of microliter blood samples. However, hematocrit-related bias in combination with subpunch analysis can result in inaccurate quantification of analytes in DBS samples. In this study we use a microfluidic DBS card, designed to automatically collect fixed volume DBS samples irrespective of the blood hematocrit, to measure caffeine concentration in normal finger prick samples obtained from 44 human individuals. Caffeine levels originating from blood drops of unknown volume collected on the volumetric microfluidic DBS card were compared to volume-controlled pipetted DBS samples from the same finger prick. Hematocrit independence and volumetric sampling performances were also verified on caffeine-spiked blood samples in vitro, using both LC-MS/MS and gravimetric methods, on hematocrits from 26 to 62%. The gravimetric measurements show an excellent metering performance of the microfluidic DBS card, with a mean blood sample volume of 14.25 μL ± 3.0% ( n = 51). A measured mean bias below 2.9% compared to normal hematocrit (47%) demonstrates that there is no significant hematocrit-induced bias. LC-MS/MS measurements confirm low CV and hematocrit independence of the sampling system and exhibit no substantial mean bias compared to pipetted DBS. Tests with 44 individuals demonstrated applicability of the microfluidic DBS card for direct finger prick blood sampling, and measured caffeine concentrations show a good agreement with measurements of pipetted DBS. The presented concept demonstrates a good volumetric performance which can help to improve the accuracy of DBS analysis by analyzing a whole spot, equivalent to a defined volume of liquid blood.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Blood Flow
Composition of Blood
Formed elements constitute the remaining 45% of the blood volume. These...
Blood Types
ABO blood group
ABO antigens are glycoproteins encoded by genes present on...
The ABO Blood Group
Antigens in the ABO Blood Group System
Antigens are substances that can trigger an immune response, leading to the production of antibodies. In the ABO blood group system,...

