Time-of-day Control Double-Order Optimization of Traffic Safety and Data-Driven Intersections

Chen Xu1, Decun Dong2, Dongxiu Ou3

  • 1The Key Laboratory of Road and Traffic Engineering, Ministry of Education, School of Transportation Engineering, Tongji University, Shanghai 201804, China. 1510706@tongji.edu.cn.

Related Concept Videos

Introduction to Membrane Traffic01:44

Introduction to Membrane Traffic

The ER, Golgi apparatus, endosomes, and lysosomes work in tandem to modify, sort, and package proteins and lipids. An integrated membrane trafficking network facilitates the back and forth shuttling of molecules within different organelles in the same cell or across the cell membrane.
The transport of soluble and membrane proteins is mediated by transport vesicles that collect cargo from one cellular compartment and deliver it to another by fusing with the target organelle membrane. The Rab...
9.5K
Survey Safety01:28

Survey Safety

Surveying near highways, rough terrain, or power lines involves significant risks. Working along highways is particularly dangerous and requires the use of warning signs and flagmen. It is safest to avoid working directly on roads and use offsets whenever possible. When highway work is unavoidable, it must follow all safety guidelines. Surveyors should wear bright clothing, such as orange reflective vests, to ensure visibility to motorists, coworkers, and hunters. In construction zones, wearing...
379
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
394
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
410
Household Wiring And Electrical Safety01:13

Household Wiring And Electrical Safety

Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.7K
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...