Related Experiment Video
Updated: Jan 27, 2026

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
High continuous positive airway pressure in neonates: A physiological study
Amit Mukerji1, Muzafar Gani Abdul Wahab1, Souvik Mitra2
1Department of Paediatrics, McMaster University, Hamilton, Ontario, Canada.
High levels of continuous positive airway pressure (CPAP) were well tolerated in preterm neonates for short periods. Further research is needed to assess safety and efficacy in neonates with severe lung disease over extended durations.
Area of Science:
- Neonatal physiology
- Respiratory support
- Cardiorespiratory monitoring
Background:
- Continuous positive airway pressure (CPAP) is a common respiratory support method for preterm neonates.
- Understanding the cardiorespiratory implications of escalating CPAP levels is crucial for optimizing treatment and patient outcomes.
Purpose of the Study:
- To evaluate the physiological cardiorespiratory effects of high continuous positive airway pressure (CPAP) levels (>8 cmH2O) in preterm neonates.
- To determine the tolerance and safety limits of increasing CPAP pressures in this vulnerable population.
Main Methods:
- Fifteen preterm neonates (postmenstrual age ≥32 weeks) on CPAP 5 cmH2O were studied.
- CPAP pressures were incrementally increased by 2 cmH2O up to 13 cmH2O, with cardiorespiratory parameters measured at each step.
- Cardiac output, electrical diaphragmatic activity (Edi), and clinical parameters were assessed, with predefined criteria for study termination.
Main Results:
- No significant differences in cardiac output were observed across CPAP levels from 5 to 13 cmH2O (P=0.99).
- Electrical diaphragmatic activity (Edi) showed a transient trend towards decline at 9 cmH2O.
- No other cardiorespiratory parameters differed significantly, and no neonate met termination criteria, indicating good tolerance.
Conclusions:
- High CPAP levels were well tolerated by preterm neonates for short-term use.
- Further research is warranted to investigate the safety and efficacy of higher CPAP levels over longer durations and in neonates with more severe lung disease.
Related Concept Videos
Position-effect Variegation
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Continuing Care
Continuity Equation
The mass flow rate is expressed as:
Continuity Equation