Semiautomatic carotid intraplaque hemorrhage volume measurement using 3D carotid MRI
Jin Liu1, Jie Sun2, Niranjan Balu2
1Department of Bioengineering, University of Washington, Seattle, Washington, USA.
Background:
Presence of intraplaque hemorrhage (IPH) is a known risk factor for stroke and plaque progression. Accurate and reproducible measurement of IPH volume are required for further risk stratification.
Purpose:
To develop a semiautomatic method to measure carotid IPH volume.
Study Type:
Retrospective.
Population:
Patients scheduled for carotid endarterectomy and patients with 16-79% asymptomatic carotid stenosis by ultrasound.
Field Strength:
3T.
Sequence:
Simultaneous noncontrast angiography and intraplaque hemorrhage (SNAP) MRI.
Assessment:
A semiautomated volumetric measurement of IPH using signal intensity thresholding of 3D SNAP volume was implemented. Fourteen carotid endarterectomy patients were enrolled to determine the signal intensity threshold of IPH using histology. Thirty-three patients with 16-79% asymptomatic stenosis were scanned twice within 1 month to evaluate reproducibility. The normalized SNAP intensity with the highest Youden index for predicting IPH on histology was used for thresholding. Scan-rescan reproducibility of IPH measurement was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV).
Statistical Tests:
Receiver operating characteristic curve, area under the curve, Cohen's kappa, intraclass correlation coefficient, coefficient of variance (CV), and paired t-test.
Results:
IPH detection by the algorithm had substantial agreement with manual review (kappa: 0.92; 95% confidence interval [CI]: 0.83, 1.00) and moderate agreement with histology (kappa: 0.55; 95% CI: 0.34, 0.68). IPH volume measurements by the algorithm were strongly correlated with histology (Spearman's rho = 0.76, P = 0.002). IPH measurements were also reproducible, with ICCs of 0.86 (95% CI: 0.57, 0.96), 0.77 (95% CI: 0.32, 0.94), and 0.99 (95% CI: 0.93, 1.00) for maximum/mean normalized intensity and IPH volume, respectively. The corresponding CVs were 10.6%, 5.2%, and 11.8%.
Data Conclusion:
IPH volume measurements on SNAP MRI are highly reproducible using semiautomatic measurement. Level of Evidence 2 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2019;50:1055-1062.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
06:30Endovascular Perforation Model for Subarachnoid Hemorrhage Combined with Magnetic Resonance Imaging MRI
Published on: December 16, 2021
Related Concept Videos
Constant Volume Calorimetry
Volume of Distribution
Work Done During Volume Change
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...