Ferroelectrics with a controlled oxygen-vacancy distribution by design

Yuji Noguchi1, Hiroki Matsuo2,3, Yuuki Kitanaka2

  • 1Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo, 113-856, Japan. yuji19700126@gmail.com.

Scientific Reports
|March 14, 2019
PubMed

Related Concept Videos

PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
646
PI Controller: Design01:24

PI Controller: Design

Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
1.2K
Design Example: Distributing Reinforcements in Concrete Sections01:22

Design Example: Distributing Reinforcements in Concrete Sections

The topic explores the practical aspects of adjusting steel reinforcements within a concrete beam section to meet specific design requirements. When designing a reinforced concrete beam, it is essential to distribute the steel reinforcements properly to ensure structural integrity and efficiency. The example provided details a scenario where a beam requires a total steel cross-section of 4 square inches. The engineer identifies that the available steel bars have a nominal diameter of 1.693...
272
Group Design02:01

Group Design

The most basic experimental design involves two groups: the experimental group and the control group. The two groups are designed to be the same except for one difference— experimental manipulation. The experimental group gets the experimental manipulation—that is, the treatment or variable being tested—and the control group does not. Since experimental manipulation is the only difference between the experimental and control groups, we can be sure that any differences between...
10.4K
Drug Distribution: Volume of Distribution01:25

Drug Distribution: Volume of Distribution

The volume of distribution refers to the theoretical volume necessary to contain the entire amount of an administered drug at the same concentration observed in the blood plasma. The body's intracellular fluid compartment, which makes up two-thirds of the total body water, is contrasted with the extracellular fluid compartment—comprising plasma and interstitial fluid—that accounts for one-third. The volume of distribution can vary depending on the characteristics of the drug.
7.4K
F Distribution01:19

F Distribution

The F distribution was named after Sir Ronald Fisher, an English statistician. The F statistic is a ratio (a fraction) with two sets of degrees of freedom; one for the numerator and one for the denominator. The F distribution is derived from the Student's t distribution. The values of the F distribution are squares of the corresponding values of the t distribution. One-Way ANOVA expands the t test for comparing more than two groups. The scope of that derivation is beyond the level of this...
10.7K