Related Experiment Video
Updated: Jan 27, 2026

Identification and Protection of the Recurrent Laryngeal Nerve during Transoral Robotic Thyroidectomy
Published on: October 24, 2025
A Compliant Transoral Surgical Robotic System Based on a Parallel Flexible Mechanism
Xiaoyi Gu1,2, Changsheng Li1, Xiao Xiao1
1Department of Biomedical Engineering, National University of Singapore, EA-05-30, 9 Engineering Drive 1, Singapore, 117575, Singapore.
Abstract:
Transoral robotic surgery (TORS) allows for access to oropharyngeal regions in an effective and minimally invasive manner. However, safe TORS access to deep pharyngeal (such as hypopharynx) sites remains a great challenge for current surgical robotic systems. In this work, we introduce a novel continuum robot with an optimized flexible parallel mechanism, to meet stringent requirements imposed by TORS on size, workspace, flexibility, and compliance. The system is comprised of two parts, a guidance part and an execution part, and achieves 11 controllable degrees of freedom. The execution part of the robot, based on the optimized flexible parallel mechanism, is able to reach deep sites in the oropharynx and larynx with the assistance of the continuum guidance part. In addition to the mechanical design, extensive analysis and experiments were carried out. Kinematic models were derived and the reachable workspace of the robot was verified to cover the entire target surgical area. Experimental results indicate that the robot achieves significantly enhanced compliance. Additionally, the designed robot can withstand a load of 1.5 N within the allowable range of the deflection. The positioning errors caused by the interference between different mechanisms can be effectively eliminated using the proposed compensation method. The maximum displacement error of this system under various conditions is less than 2 mm and the maximum bending error is less than 7.5°, which are satisfied for TORS. Cadaver trials were conducted to further demonstrate the feasibility. The reduced setup time and the reduced time to access the target site indicate that the developed surgical robotic system can achieve better operative efficiency in TORS when compared with current systems.
More Related Videos
03:55Author Spotlight: Enhancing Grasping Abilities for Hemiplegic Patients with Flexible Robotic Limbs
Published on: October 27, 2023
04:01Transoral Robotic Total Thyroidectomy and Bilateral Central Regional Lymph Node Dissection for Papillary Thyroid Carcinoma
Published on: September 15, 2023
Related Concept Videos
Parallel Resonance
Parallel Processing
Resistors In Parallel
Series and Parallel Capacitors
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...
Parallel-axis Theorem
Series and Parallel Inductors
For a series connection of N inductors, each carrying the same current, applying Kirchhoff's voltage law unveils a crucial relationship. Substituting the expression for...