Optical Sectioning and Visualization of the Intervertebral Disc from Embryonic Development to Degeneration
Published on: July 8, 2021
Effect of needle diameter, type and volume of contrast agent on intervertebral disc degeneration in rats with
Xiaodong Huang1, Weiheng Wang1, Qingxi Meng1
1Department of Orthopaedics, Changzheng Hospital, Second Military Medical University, 415 Fengyang Road, Shanghai, 200003, China.
Purpose:
Discography can increase disc degeneration, but the influence of different discography variables on the degeneration of discs has not been reported. The aim of this study was to investigate the effects of discography variables of needle diameter, type of contrast agent and volume of contrast agent on disc degeneration.
Methods:
Three separate experiments examined needle diameter, and type and volume of contrast agent. Coccygeal discs (Co7-10) adult male rats were used. X-rays were used to detect the disc height degeneration index at 1, 2 and 4 weeks after the procedure. MRI was used to study the changes in the disc structure and the signal intensity of IVD 2 and 4 weeks after the procedure. Disc water content and histology were measured at 4 weeks after the procedure.
Results:
A 21-g needle significantly increased disc degeneration when compared with the 30-g needle as detected by X-ray, MRI, disc water content and histology (P < 0.05). Two microlitres of iodine significantly decreased the disc MRI signal and water content at 4 weeks compared with the same volume of normal saline (P < 0.05). Three microlitres of iodine significantly increased disc degeneration when compared with 2 µl iodine, as detected by X-ray, MRI, disc water content and histology at 4 weeks (P < 0.05).
Conclusion:
To reduce disc degeneration after discography, it may be best to choose a smaller needle size, minimize the use of contrast agent and use non-ionic contrast agents with osmotic pressure similar to the intervertebral disc. These slides can be retrieved under Electronic Supplementary Material.
Related Concept Videos
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Constant Volume Calorimetry
Volume of Distribution
Work Done During Volume Change
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...