Repeatability of two subjective accommodative amplitude measurements and agreement with an objective method
Yunyun Chen1, Chuanchuan Zhang1, Chenglu Ding1
1School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China.
The minus-lens method is more accurate for measuring accommodative amplitude (AA) than the modified push-up method. The minus-lens method with sustained blur is optimal for subjective AA assessment in adults.
Area of Science:
- Ophthalmology
- Optometry
- Vision Science
Background:
- Accurate measurement of accommodative amplitude (AA) is crucial for understanding visual function.
- Subjective methods like the modified push-up and minus-lens techniques are commonly used but their repeatability and agreement with objective measures vary.
- Assessing the reliability of these subjective methods is essential for clinical practice.
Purpose of the Study:
- To compare the repeatability of subjective accommodative amplitude (AA) measurements using the modified push-up and minus-lens methods.
- To determine the agreement between subjective AA measurements and objective AA measured by an autorefractor.
- To identify the optimal subjective method for assessing accommodative amplitude in adults.
Main Methods:
- Subjective accommodative amplitude (AA) was measured in 47 adults (aged 22-30 years) using the modified push-up and minus-lens methods.
- Measurements were repeated three times for each method, using both first sustained blur and unreadable criteria.
- Objective AA was measured using an open-field autorefractor, with minus-lens simulation.
Main Results:
- Accommodative amplitude (AA) values differed significantly based on the measurement method (p < 0.001).
- The minus-lens method with the first sustained blur criterion yielded AA values closest to the objective autorefractor measurements (10.10 ± 1.71 D vs. 9.01 ± 1.49 D).
- The minus-lens method demonstrated better agreement with objective AA than the modified push-up method, with the first sustained blur criterion showing the highest agreement.
Conclusions:
- The subjective minus-lens method is more accurate for assessing accommodative amplitude (AA) in adults compared to the modified push-up method.
- The minus-lens method employing the first sustained blur criterion is the optimal technique for subjective AA assessment.
- The minus-lens method with the unreadable criterion is also clinically applicable, though it yields slightly higher AA values.
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Potential Due to a Polarized Object
Potential Due to a Magnetized Object
The vector...
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems...
Cable Subjected to Concentrated Loads