Effects of ventilation openings in industrial safety helmets on evaporative heat dissipation
Satoru Ueno1, Shin-Ichi Sawada1
1National Institute of Occupational Safety and Health, Kawasaki, Japan.
Objectives:
This study aimed to investigate the effects of ventilation openings in commercial industrial safety helmets (ISHs) on evaporative heat dissipation.
Methods:
Seven models of commercial ISH were examined quantitatively by a sweating thermal head manikin (SHM) with six separate zones. To simulate summer outdoor conditions, the measurements were done in a climate chamber, with the room temperature and relative humidity set at 34.0°C and 50%, respectively. The shell temperature of SHM was set at 34.0°C. Wind was blown from the front or left side at 1.0, 2.0, and 3.0 m/s. The necessary heat flux to keep the manikin skin temperature at 34.0°C was counted as evaporative heat dissipation in each zone.
Results:
Openings at the front and back, and openings between the body and brim of the helmet played a significant role in increasing the heat flux in Forehead zone, but in all zones as a total, the effects were not significant. Heat flux for ISH with openings on both the right and left sides was not significantly different from that without openings.
Conclusions:
Our study utilizing SHM showed that ventilation openings on both the right and left sides or front and back sides of commercial ISHs were not significantly effective in increasing total evaporative heat dissipation under an equivalent temperature of ambience and manikin shell. Further improvements on ISH are needed to increase evaporative heat dissipation.
More Related Videos
Related Concept Videos
Spanning Openings in Brick Walls
Lintels are primary supports used to span openings and can be crafted from materials such as reinforced concrete, steel-reinforced brick masonry, or simple steel angles. These are straightforward to install and are typically concealed...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Power Dissipated in a Circuit: Problem Solving
The simplest combinations of resistors are series and parallel connections. In a series circuit, the first resistor's output current flows into the second resistor's input; therefore, each resistor's current is the same. Thus, the equivalent resistance is the algebraic sum of the resistances. The current through the circuit can be found from Ohm's law and is equal to the...
Survey Safety
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...