Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Median01:08

Median

28.9K
Besides mean, the median is a widely used measure of central tendency. Typically, median is defined as the central or middle value of a data set, measured by arranging the data elements in an increasing or decreasing order. Since this middle value is not affected by the precise numerical values of the outliers or fluctuations, it is insensitive to them. Hence, in cases where a data set may have outliers or the extreme values are not known, the median is a better measure of the central tendency...
28.9K
Sign Test for Median of Single Population01:20

Sign Test for Median of Single Population

353
In general, the sign test serves as a nonparametric method to test hypotheses about the median of a single population when the data does not follow a known distribution. This simplicity makes it particularly useful for small sample sizes or when the assumptions of parametric tests cannot be met. The process begins with identifying a null hypothesis, typically stating that the population median equals a specific value. The alternative hypothesis could be that the median is either not equal to,...
353
Passive Filters01:27

Passive Filters

1.0K
Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
1.0K
Active Filters01:25

Active Filters

1.3K
Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
1.3K
Wilcoxon Signed-Ranks Test for Median of Single Population01:14

Wilcoxon Signed-Ranks Test for Median of Single Population

454
The Wilcoxon signed-rank test for the median of a single population is a nonparametric test used to evaluate whether the median of a population differs from a specified value. Unlike parametric tests, it does not require data to follow a normal distribution, making it suitable for non-normal or small samples. The test begins by calculating the difference (d) between each observation and the hypothesized median. The absolute values of these differences are ranked in ascending order, with ties...
454
Microsoft Excel: Median, Quartile range, and Box Plots01:29

Microsoft Excel: Median, Quartile range, and Box Plots

3.2K
In Microsoft Excel, calculating the median, interquartile range, and creating box plots can help understand the distribution of your data.
Median and Quartile Range: The median is calculated using the formula `=MEDIAN(range)', which provides the middle value of your data set. Quartiles divide your data into four equal parts. To find the first and third quartiles, use ‘=QUARTILE(range, 1)' and ‘=QUARTILE(range, 3)', respectively. The interquartile range (IQR), which...
3.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An Open Multifunctional FPGA-Based Pulser/Receiver System for Intravascular Ultrasound (IVUS) Imaging and Therapy.

Sensors (Basel, Switzerland)·2025
Same author

Improving Ultrasound B-Mode Image Quality with Coherent Plane-Wave Compounding Using Adaptive Beamformers Based on Minimum Variance.

Sensors (Basel, Switzerland)·2025
Same author

Generation and Analysis of Ultrasound Images Using Plane Wave and Sparse Arrays Techniques.

Sensors (Basel, Switzerland)·2018
Same author

Polystyrene Oxygen Optodes Doped with Ir(III) and Pd(II) meso-Tetrakis(pentafluorophenyl)porphyrin Using an LED-Based High-Sensitivity Phosphorimeter.

Sensors (Basel, Switzerland)·2018
Same author

An Assessment of Iterative Reconstruction Methods for Sparse Ultrasound Imaging.

Sensors (Basel, Switzerland)·2017
Same author

Electrophysiologic characteristics of tremor in Parkinson's disease and essential tremor.

Arquivos de neuro-psiquiatria·2014
Same journal

Lung cancer multimodal auxiliary diagnosis based on entropy weight decision fusion.

Biomedical engineering online·2026
Same journal

Potentials of BMSCs for regulating osteogenic-vascular-neural-lymphatic coupling in bone regeneration.

Biomedical engineering online·2026
Same journal

Protein adsorption at material interface: mechanistic design framework for engineering ceramic scaffolds for bone repair applications.

Biomedical engineering online·2026
Same journal

Machine learning models of segmentation in acute ischemic stroke: a systematic review and meta-analysis.

Biomedical engineering online·2026
Same journal

The influence of successful septal myectomy on myocardial stress distributions in the left ventricle: a computational analysis.

Biomedical engineering online·2026
Same journal

Resting-state brain network alterations in adolescent idiopathic scoliosis using functional near-infrared spectroscopy.

Biomedical engineering online·2026
See all related articles

Related Experiment Video

Updated: Jan 27, 2026

Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
05:56

Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis

Published on: August 29, 2025

480

Image reconstruction utilizing median filtering applied to elastography.

Rubem P Carbente1, Joaquim M Maia2, Amauri A Assef2

  • 1Electrical Engineering Department and the Graduate School of Electrical Engineering (DAELT), Federal University of Technology-Paraná (UTFPR), Curitiba, PR, Brazil. rubem@utfpr.edu.br.

Biomedical Engineering Online
|March 15, 2019
PubMed
Summary
This summary is machine-generated.

This study introduces a new ultrasound elastography method for assessing tissue viscoelasticity. The technique accurately quantifies mechanical properties, aiding in noninvasive disease diagnosis and monitoring.

Keywords:
ElastographyShear waveSignal processingUltrafast imagingUltrasound

More Related Videos

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
07:13

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH

Published on: April 20, 2021

4.5K
Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment
04:51

Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment

Published on: March 1, 2024

1.5K

Related Experiment Videos

Last Updated: Jan 27, 2026

Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
05:56

Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis

Published on: August 29, 2025

480
Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
07:13

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH

Published on: April 20, 2021

4.5K
Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment
04:51

Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment

Published on: March 1, 2024

1.5K

Area of Science:

  • Medical Imaging
  • Biophysics
  • Ultrasound Technology

Background:

  • Ultrafast ultrasound imaging enables assessment of tissue viscoelasticity by detecting shear waves.
  • This elastography technique allows for noninvasive diagnosis and monitoring of diseases through mechanical property quantification.

Purpose of the Study:

  • To present a novel method for estimating viscoelastic properties and rigidity using shear wave elasticity imaging (SWEI).
  • To validate the technique's accuracy using an elastography phantom with known mechanical properties.

Main Methods:

  • Utilized Verasonics Vantage 128 research platform and L11-4v transducer for radio frequency signal acquisition.
  • Employed an elastography phantom (model 049A, CIRS) for data collection.
  • Processed and analyzed data using MATLAB, applying a novel filtering function for elastographic image generation.

Main Results:

  • The proposed SWEI technique successfully generated qualitative images reflecting altered viscoelastic properties in phantom inclusions.
  • Results demonstrated good agreement with manufacturer-indicated margins of error, with mean percentage errors ranging from -6.5% to -28.2%.
  • Median filtering characteristics were observed to smooth velocity variations, enhancing elastographic image quality.

Conclusions:

  • The developed SWEI technique optimizes elastographic images through a unique filtering function that considers local mean velocity.