Objectives:
Noninvasive online monitoring of different particle flows from the airways may serve as an additional tool to assess mechanical ventilation. In the present study, we used a customised PExA, an optical particle counter for monitoring particle flow and size distribution in exhaled air, to analyse airway particle flow for three subsequent days. We compared volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) and performed recruitment manoeuvres (RM).
Methods:
Six animals were randomised into two groups: half received VCV before PCV and the other half received PCV before VCV. Measurements were taken daily for 1 h in each mode during three subsequent days in six fully anaesthetised domestic pigs. A RM was performed twice daily for 60 s at positive end-expiratory pressure (PEEP) of 10, 4 breaths/min and inspiratory-expiratory ratio (I:E) of 2:1. Measurements were taken for 3 min before the RM, 1 min during the RM and for 3 min after the RM. The particle sizes measured were between 0.48 and 3.37 μm.
Results:
A significant stepwise decrease was observed in total particle count from day 1 to day 3, and at the same time, an increase in fluid levels was seen. Comparing VCV to PCV, a significant increase in total particle count was observed on day 2, with the highest particle count occurring during VCV. A significant increase was observed comparing before and after RM on day 1 and 2 but not on day 3. One animal developed ARDS and showed a different particle pattern compared to the other animals.
Conclusions:
This study shows the safety and useability of the PExA technique used in conjunction with mechanical ventilation. We detected differences between the ventilation modes VCV and PCV in total particle count without any significant changes in ventilator pressure levels, FiO2 levels or the animals' vital parameters. The findings during RM indicate an opening of the small airways, but the effect is short lived. We have also showed that VCV and PCV may affect the lung physiology differently during recruitment manoeuvres. These findings might indicate that this technique may provide more refined information on the impact of mechanical ventilation.
Related Concept Videos
Control Volume and System Representations
The control volume approach considers a stationary region in space through which fluid flows. This region is bounded by a control surface. For instance, in the case of water...
Linear Momentum in Control Volume
Conservation of Energy in Control Volume
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
Control of Power Flow
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...