Related Experiment Video
Updated: Jan 27, 2026

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field
Haruna Nakazawa1, Marika Doi2, Emiyu Ogawa2
1School of Fundamental Science and Technology, Graduate School of Science and Technology, Keio University, 3-14-1, Hiyoshi, Kohoku-ku, Yokohama City, Kanagawa, 223-8522, Japan. h.nakazawa@arai.appi.keio.ac.jp.
Abstract:
To measure the few millimeter-scale macroscopic optical properties of biological tissue, including the scattering coefficient, while avoiding the instability that originates from sample slicing preparation processes, we performed propagated light intensity measurements through an optical fiber that punctures the bulk tissue while varying the fiber tip depth and the field of view (FOV) at the tip; the results were analyzed using the inverse Monte Carlo method. We realized FOV changes at the fiber tip in the bulk tissue using a variable aperture that was located outside the bulk tissue through a short high-numerical aperture (high-NA) multi-mode fiber with a quasi-straight shape. Using a homogeneous optical model solution, we verified the principle and operation of the constructed experimental system. A 200-μm-core-diameter silica fiber with NA of 0.5 and length of 1 m installed in a 21G needle was used. The detection fiber's shape was maintained over a radius of curvature of 30 cm. The dependences of the detected light intensity on the FOV and the depth showed better than 1.4% accuracy versus calculated dependences based on the measured optical properties of the solution. Adaptation of the method for use with complex structured biological tissue, particularly in the presence of a thick fascia, was not completely resolved. However, we believe that our specific fiber puncture-based measurement method for use in bulk tissue based on variation of the FOV with inverse Monte Carlo method-based analysis will be useful in obtaining optical coefficients while avoiding sample preparation-related instabilities.
Related Concept Videos
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...
Connective Tissue Fibers and Ground Substance
Fiber Reinforced Concrete
Types of Skeletal Muscle Fibers
Fast-twitch fibers
Fast-twitch fibers, or Type II fibers, are designed for quick, powerful bursts of speed and strength. They reach peak tension within approximately 0.01 seconds following stimulation. Characterized by a large diameter and densely packed myofibrils, these fibers contain...
Formation of Muscle Fibers from Myoblasts
Muscle progenitor cells (MPCs) are formed from the myotomes. MPCs express genes that encode the transcription factors Pax3 and Pax7. Along with Pax 3/7, other transcription...
Local Anesthetics: Differential Sensitivity of Nerve Fibers

