Gastric accommodation measurements by single photon emission computed tomography and two-dimensional scintigraphy in
Victor Chedid1, Houssam Halawi1, Justin Brandler1
1Division of Gastroenterology and Hepatology, Clinical Enteric Neuroscience Translational and Epidemiological Research (CENTER), Mayo Clinic, Rochester, Minnesota.
Objective:
To compare estimates of gastric accommodation (GA) with single photon emission computed tomography (SPECT) to measurements based on intragastric meal distribution immediately post-meal ingestion (IMD0 ).
Methods:
We evaluated 108 diabetics with upper gastrointestinal (UGI) symptoms who had undergone gastric emptying of solids (GE) by scintigraphy and GA measurements by SPECT. Immediately after ingestion of a 99m Tc-labeled egg meal (time 0), we estimated IMD0 as radioactive counts or area of the proximal half of the stomach on two-dimensional images. Gastric volume (GV) during fasting and after 300 mL Ensure® was measured by SPECT to quantify accommodation volume (AV) or postprandial to fasting volume ratio (GVR). From the measured proximal gastric area, we estimated the volume of proximal stomach (4/3 × π × r3 ). We performed regression analyses to assess relationships between IMD0 and GA (AV) and GVR.
Results:
There was a significant correlation between area and radioactivity counts in the proximal stomach (r = 0.67, P < 0.001); however, there was considerable interpersonal variation [bias 0.20 (95% CI -0.07, 0.47)]. There were no significant correlations between total GV or AV or VR by SPECT and measurements using IMD0 : proximal gastric counts, area, and estimated volume as continuous variables of dichotomized patient groups, based on published cutoff values. There were no significant differences in total gastric area or the IMD0 parameters (% area or % radioactive counts) between those with and without UGI symptoms except for fullness and satiety.
Conclusions:
Intragastric meal distribution immediately post-meal ingestion is not significantly correlated with GA measurement by SPECT.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Diabetes: Symptoms, Diagnosis, and Complications
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Emission Spectra
Imaging Studies III: Computed Tomography