Related Experiment Video
Updated: Jan 27, 2026

Athymic Rat Model for Evaluation of Engineered Anterior Cruciate Ligament Grafts
Published on: March 26, 2015
Variation in Graft Bending Angle During Range of Motion in Single-Bundle Posterior Cruciate Ligament Reconstruction:
Min Up Kim1, Jae Won Kim2, Man Soo Kim3
1Department of Orthopedic Surgery, Incheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Purpose:
To compare variations in femoral graft bending angle during range of motion (ROM) of the knee between inside-out (IO) and retro-socket outside-in (OI) techniques in posterior cruciate ligament (PCL) reconstruction using in vivo 3-dimensional (3D) computed tomography analysis.
Methods:
Ten patients underwent PCL reconstruction by the IO technique (5 patients) or the retro-socket OI technique (5 patients) for suspensory femoral fixation. After PCL reconstruction, 3D computed tomography was performed in 0° extension and 90° flexion to reconstruct 3D femur and tibia bone models using Mimics software. Positions of femur and tibia at 30°, 45°, and 60° flexion were reproduced by determining the kinematic factors of anteroposterior translation, mediolateral translation, and internal-external rotation angle of each patient based on previously measured kinematic data. Variation in graft bending angle according to the flexion range of the knee was calculated by the difference in graft angulation measured at each flexion angle. The results were compared between the 2 techniques.
Results:
There was significant difference in variation of femoral graft bending angle between IO and retro-socket OI techniques from 0° to 90° flexion of the knee (P = .008). Significant difference was also noticed at 30° to 45° (P = .008), 45° to 60° (P = .008), and 60° to 90° (P = .016) ROM of the knee between the 2 groups.
Conclusions:
The retro-socket OI technique resulted in less variation in femoral graft bending angle compared with the IO technique during knee ROM. We recommend the retro-socket OI technique for femoral tunnel placement to reduce the graft motion at the intra-articular femoral tunnel aperture.
Clinical Relevance:
The retro-socket OI technique produces significantly less variation in femoral graft bending angle when compared with the IO technique. Such reduction in variation of femoral graft bending angle might be related to lower stress at the femoral tunnel aperture.
More Related Videos
05:07Author Spotlight: Implementing the Enhanced Recovery After Surgery Concept in Rehabilitation Following Anterior Cruciate Ligament Reconstruction
Published on: March 1, 2024
05:44Author Spotlight: Double Posteromedial Approach for Treating Posterior Cruciate Ligament Cysts
Published on: October 20, 2023
Related Concept Videos
Variation: Normal Distribution, Range, and Standard Deviation
Angle of Twist - Elastic Range
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Design Example: Traverse Angle Computations
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...