Related Experiment Video
Updated: Jan 27, 2026

Covalent Binding of BMP-2 on Surfaces Using a Self-assembled Monolayer Approach
Published on: August 26, 2013
Wastewater biofilm formation on self-assembled monolayer surfaces using elastomeric flow cells
Arslan Siddique1, Benjaphon Suraraksa2, Mati Horprathum3
1Biotechnology Division, School of Bioresources and Technology, King Mongkut's University of Technology Thonburi, Bang Khun Thian, Bangkok, 10150, Thailand.
Abstract:
In anaerobic wastewater treatment, microbial biofilm is beneficial for efficient substrate utilization and for preventing the wash-out of key microorganisms. By providing solid supports, biofilm formation can be accelerated due to the early initial adhesion of residing microbes. Alteration in surface properties is therefore one such approach that helps us understand microbial interfacial interaction. Here, self-assembled monolayers of alkanethiols with carboxyl (-COOH), hydroxyl (-OH), and amine (-NH2) terminal moieties on gold (Au) substrates were employed to study the initial adhesion of wastewater microbes. An elastomeric flow cell was also utilized to simulate the environment of wastewater bioreactor. Results from fluorescence in situ hybridization (FISH) portrayed more enhanced microbial adhesion after 2 h on -NH2 functional group with the calculated surface coverage of 12.8 ± 2.4% as compared to 7.7 ± 1.6% on -COOH, 11.0 ± 2.0% on -OH, and 1.2% on unmodified Au surfaces. This might be because of concomitant electrostatic attraction between negatively-charged bacteria and positively-charged (-NH3+) functional groups. Nevertheless, the average surface coverage by individual biofilm clusters was 28.0 ± 5.0 μm2 and 32.0 ± 9.0 μm2 on -NH2 and -OH surfaces, respectively, while -COOH surfaces resulted in higher value (60.0 ± 5.0 μm2) and no significant cluster formation was observed on Au surfaces. Accordingly, the average inter-cluster distance observed on -NH2 surfaces was relatively smaller (3.0 ± 0.6 μm) as compared to that on other surfaces. Overall, these data suggest favorable initial biofilm growth on more hydrophilic and positively-charged surfaces. Furthermore, the analysis of the mean fluorescence intensity revealed preferred initial adhesion of key microbes (archaea) on -OH and -NH2 surfaces. Indeed, results obtained from this study would be beneficial in designing selective biointerfaces for certain biofilm carriers in a typical wastewater bioreactor. Importantly, our elastomeric flow cell integrated with SAM-modified surfaces demonstrated an ideal platform for high-throughput investigation of wastewater biofilm under controlled environments.
Related Concept Videos
Cell-surface Signaling
Biofilms
Formation of Species
Protein Complex Assembly
Many viruses self-assemble into a fully functional unit using the infected host cell to...
Zygotic Development And Stem Cell Formation
Solution Formation
This selective...

