Not your usual hip pain: necrotising fasciitis secondary to sigmoid perforation

Sarthak Soin1, Sumathi Vijaya Rangan1, Faisal Shaukat Ali1

  • 1Internal Medicine, Presence Saint Joseph Hospital Chicago, Chicago, Illinois, USA.

BMJ Case Reports
|March 16, 2019
PubMed

Insights

Necrotising fasciitis (NF) from sigmoid perforation is rare but life-threatening. Early surgery and antibiotics are crucial for successful outcomes in this severe condition.

Area of Science:

  • Gastroenterology
  • Infectious Diseases
  • Surgical Oncology

Background:

  • Necrotising fasciitis (NF) is a severe soft tissue infection.
  • Sigmoid perforation is an uncommon cause of NF, posing significant risks.

Observation:

  • A 65-year-old male with stage 4 rectal cancer presented with hip pain.
  • Imaging revealed sigmoid perforation with gas extending to the posterior thigh.

Findings:

  • Early surgical intervention and broad-spectrum antibiotics were critical.
  • Successful management of sigmoid perforation leading to NF was achieved.

Implications:

  • This case highlights the potential for lethal complications from sigmoid perforation.
  • Highlights the importance of prompt diagnosis and aggressive treatment for NF secondary to intra-abdominal sources.

Related Concept Videos

Esophageal Perforation-I: Introduction01:22

Esophageal Perforation-I: Introduction

Esophageal perforation is a severe medical condition characterized by a breach in the integrity of the esophageal wall. This breach can occur due to various factors such as trauma, medical procedures, or underlying diseases. When the esophageal wall is compromised, it allows food, fluids, and digestive juices into the chest cavity or adjacent structures, leading to potential complications and health risks.
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
589
Secondary Active Transport01:55

Secondary Active Transport

One example of how cells use the energy contained in electrochemical gradients is demonstrated by glucose transport into cells. The ion vital to this process is sodium (Na+), which is typically present in higher concentrations extracellularly than in the cytosol. Such a concentration difference is due, in part, to the action of an enzyme “pump” embedded in the cellular membrane that actively expels Na+ from a cell. Importantly, as this pump contributes to the high concentration of...
137.7K
Secondary Active Transport01:32

Secondary Active Transport

One example of how cells use the energy contained in electrochemical gradients is demonstrated by glucose transport into cells. The ion vital to this process is sodium (Na+), which is typically present in higher concentrations extracellularly than in the cytosol. Such a concentration difference is due, in part, to the action of an enzyme "pump" embedded in the cellular membrane that actively expels Na+ from a cell. Importantly, as this pump contributes to the high concentration of...
9.5K
Secondary Healthcare System01:11

Secondary Healthcare System

Secondary healthcare is offered by a specialist, generally in hospitals or clinics for patients referred by primary healthcare providers. It occurs when a person has an illness or injury that requires specific medical care. Secondary care is often referred to as acute care. Secondary care can range from uncomplicated care to repair a minor laceration or treat a strep throat infection to more complicated emergent care, such as treating a head injury sustained in an automobile accident. Whatever...
2.0K
Primary and Secondary Growth in Roots and Shoots03:02

Primary and Secondary Growth in Roots and Shoots

Vascular plants, which account for over 90% of the Earth’s vegetation, all undergo primary growth—which lengthens roots and shoots. Many land plants, notably woody plants, also undergo secondary growth—which thickens roots and shoots.
60.4K
Secondary Distribution01:25

Secondary Distribution

Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
571