Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
Image-guided vibrometry system integrated with spectral- and time-domain optical coherence tomography
Abstract:
Vibrometry using optical coherence tomography (OCT) can provide valuable information for investigating either the mechanical properties or the physiological function of biological tissues, especially the hearing organs. Real-time imaging of the measured tissues provides structure imaging and spatial guidance for and is thus highly demanded by such vibrometry. However, the traditional time-domain OCT (TD-OCT) systems, although capable of subnanometric vibrometry at large ranges of frequencies, are unable to offer an imaging speed that is high enough to acquire depth-resolved images for guidance. The spectral-domain OCT (SD-OCT) systems, although allowing image-guided vibrometry, are challenged in measuring vibration at high frequencies, particularly for scattering tissue specimens that require longer exposure time to ensure imaging and vibrometry performance. This is because of their limit in the line-scan rate of the CCD, in which the maximum resolvable frequency measured by the SD-OCT is about 1/4 of the CCD line-scan rate in practice. In the present study, we have developed a dual-mode OCT system combining both SD-OCT and TD-OCT modalities for image-guided vibrometry, as the SD-OCT can provide guiding structural images in real-time and, moreover, the TD-OCT can guarantee vibrometry at large ranges of frequencies, including high frequencies. The efficacy of the developed system in image-guided vibrometry has been experimentally demonstrated using both piezoelectric ceramic transducer (PZT) and ex vivo middle-ear samples from guinea pigs. For the vibrometry of PZT, the minimum detectable vibration amplitude was reached at ∼0.01 nm. For the vibrometry of the sound-evoked biological samples, both real-time two-dimensional imaging and subnanometric vibrometry were performed at the frequency ranging from 1 to 40 kHz. These results indicate that our dual-mode OCT system is able to act as an excellent vibrometer enabling image-guided high-frequency measurement.
More Related Videos
Related Concept Videos
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
The Integrated Rate Law: The Dependence of Concentration on Time
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...