Refractive index of human red blood cells between 290 nm and 1100 nm determined by optical extinction measurements
Jonas Gienger1, Kathrin Smuda2,3, Ralph Müller2
1Physikalisch-Technische Bundesanstalt (PTB), Abbestraße 2-12, 10587, Berlin, Germany. jonas.gienger@ptb.de.
Abstract:
The knowledge of optical properties of biological cells is essential to interpret their interaction with light and to derive morphological information and parameters associated with cell function like the oxygen transport capacity of human red blood cells (RBCs). We present a method to determine the dependence between the refractive index (RI) of human RBCs and their intracellular hemoglobin (Hb) concentration from spectral extinction measurements of a cell suspension. The procedure is based on the analysis of the corresponding ensemble averaged extinction cross section [Formula: see text]. Thus far two complementary approaches have been taken to derive RIs of RBCs. The first one uses homogeneous macroscopic samples prepared by hemolysis for the destruction of the RBCs' membranes and subsequent centrifugation. A second approach is the determination of RIs of single intact cells by microscopic investigation. These techniques are limited to a few discrete wavelengths or a rather narrow wavelength range. In addition most of these techniques require additional information about the concentration dependence. In contrast, our approach yields the RI increment with Hb concentration of intact, reversibly isovolumetrically sphered, oxygenated RBCs over a wide wavelength range from 290 nm to 1100 nm from macroscopic measurements.
Related Concept Videos
Generalization, Discrimination, and Extinction
Generalization occurs when a behavior reinforced in one context is performed in similar situations. For instance, a student who studies diligently for calculus and receives excellent grades might apply the same study habits to psychology and history, expecting similar results. Generalization shows how learning in one setting can influence behavior in...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Red Algae
Chromatin Packaging
The chromatin
In combination with specialized DNA binding protein called Histones, the DNA double helix forms a compact DNA: protein complex called chromatin. The chromatin itself is further compacted into higher-order...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.