Abstract:
Non-adherence to antipsychotic medication is a primary factor in disease relapse in schizophrenic patients. We sought to evaluate if plasma concentrations of the antipsychotic risperidone can be used as a predictor of treatment adherence and to identify the optimal plasma concentration threshold to reliably distinguish between adherent and non-adherent patients. A population pharmacokinetic model was used to simulate plasma risperidone steady-state trough concentrations in 1000 virtual patients, where 60% of the patients were 100% adherent to their medication, while 40% of the patients were non-adherent to their medication. The probability of adherence was assessed by receiver operating characteristic (ROC) analysis on Ctrough. The area under the ROC curve (AUCROC) was used to identify the optimal Ctrough threshold. Single vs multiple Ctrough at steady state was also evaluated. After a single risperidone Ctrough measurement, the AUCROC (95% CI) was estimated to be 0.71 (0.69-0.72) and the optimal Ctrough threshold accounting for the lowest number of adherent and non-adherent misclassifications was estimated to be 11.9 ng/mL. After multiple Ctrough measurements, the AUCROC (95% CI) increased up to 0.85 (0.84-0.87) for three Ctrough measurements. The optimal probability threshold to reliably discriminate between adherent and non-adherent patients was estimated to be 0.51. Using this model which is reflective of typical adherence to antipsychotic medication, we found that three consecutive steady-state Ctrough measurements are needed for an accurate and precise diagnostic test to discriminate between patients who are adherent or non-adherent to treatment.
More Related Videos
09:38Determining Pain Detection and Tolerance Thresholds Using an Integrated, Multi-Modal Pain Task Battery
Published on: April 14, 2016
08:52Psychophysical Tracking Method to Assess Taste Detection Thresholds in Children, Adolescents, and Adults: The Taste Detection Threshold TDT Test
Published on: April 21, 2021
Related Concept Videos
Receiver Operating Characteristic Plot
Drug Concentrations: Measurements
Plasma...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Characteristics of Life