Minimum variance based fusion of fundamental and second harmonic ultrasound imaging: Simulation and experimental study
Related Experiment Video
Updated: Jan 27, 2026

An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
Mehdi Haji Heidari Varnosfaderani1, Babak Mohammadzadeh Asl1
1Department of Biomedical Engineering, Tarbiat Modares University, Tehran, Iran.
Abstract:
Harmonic imaging is widely used in clinical ultrasound due to its higher resolution in comparison with fundamental mode. However, the low amplitude of harmonic components in this imaging method is a crucial problem, resulting in a high sensitivity to noise, while the fundamental imaging is more robust against noise. To exploit the benefits of both the fundamental and harmonic imaging, we propose a minimum variance (MV)-based adaptive combination of fundamental and harmonic images. The performance of the proposed mixing-together MV (MTMV) beamformer is evaluated on simulated and experimental RF data. The results of the simulated point targets show that in the regions near of point targets, where the desire signals exist, the proposed MTMV beamformer mostly follows the MV-beamformed harmonic image to retain a better resolution. In the regions far from the point targets, where there is just noise, it follows the MV-beamformed fundamental image to benefit from more robustness. Also, the results of the simulated and experimental cyst phantoms indicate that MTMV reduces the background noise level and improves the contrast without compromising the high resolution of the MV-beamformed harmonic image. In the simulated cyst phantom, in comparison to DAS (fundamental), DAS (harmonic), MV (fundamental), MV (harmonic), and wavelet fusion, the image contrast ratio (CR) is increased, in average, about 5.2 dB, 3.5 dB, 1.5 dB, 3.6 dB, and 2.8 dB, respectively. The contrast-to-noise ratio (CNR) is significantly improved; about 59%, 53%, 41%, 37%, and 24%, respectively. In the experimental cyst phantom, these relative improvements are about 6.6 dB, 3.5 dB, 4.2 dB, 2.1 dB, and 3.8 dB for CR, and about 64%, 52%, 25%, 33%, and 33%, for CNR, respectively.
More Related Videos
05:04Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Related Concept Videos
Harmonic Mean
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
Variance
The standard deviation measures the spread in the same units as the data....
Fundamental Attribution Error
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Fundamental Theorem of Calculus I