Related Experiment Video
Updated: Jan 27, 2026

Monitoring Tumor Metastases and Osteolytic Lesions with Bioluminescence and Micro CT Imaging
Published on: April 14, 2011
A novel image-based retrieval system for characterization of maxillofacial lesions in cone beam CT images
Fatemeh Abdolali1, Reza Aghaeizadeh Zoroofi2, Yoshito Otake3
1Control and Intelligent Processing Center of Excellence, School of Electrical and Computer Engineering, University College of Engineering, University of Tehran, P.O.Box 14395-515, North Kargar St., Tehran, Iran. f.abdolali@ut.ac.ir.
Purpose:
The objective of medical content-based image retrieval (CBIR) is to assist clinicians in decision making by retrieving the most similar cases to a given query image from a large database. Herein, a new method for content-based image retrieval of cone beam CT (CBCT) scans is presented.
Methods:
The introduced framework consists of two main phases: training database construction and querying. The goal of the training phase is database construction, which consists of three main steps. First, automatic segmentation of lesions using 3D symmetry analysis is performed. Embedding the prior shape knowledge of the 3D symmetry characteristics of the healthy human head structure increases the accuracy of automatic segmentation. Then, spatial pyramid matching is used for feature extraction, and the relative importance of each feature is learned using classifiers.
Results:
The method was applied to a dataset of 1145 volumetric CBCT images with four classes of maxillofacial lesions. A symmetry-based analysis model for automatic lesion segmentation was evaluated using similarity measures. Mean Dice coefficients of 0.89, 0.85, 0.92, and 0.87 were achieved for maxillary sinus perforation, radiolucent lesion, unerupted tooth, and root fracture classes, respectively. Moreover, the execution time of automatic segmentation was reduced to 3 min per case. The performance of the proposed search engine was evaluated using mean average precision and normalized discounted cumulative gain. A mean average retrieval accuracy and normalized discounted cumulative gain of 0.90 and 0.92, respectively, were achieved.
Conclusion:
Quantitative results show that the proposed approach is more effective than previous methods in the literature, and it can facilitate the introduction of CBIR in clinical CBCT applications.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Retrieval
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...
ER Retrieval Pathway
The ER uses many checkpoints to prevent the entry of incorrectly folded or a resident protein as cargo onto a transport vesicle. These mechanisms...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...

