Related Experiment Video
Updated: Jan 27, 2026

A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
Published on: January 18, 2018
A simple dilute-and-shoot method for screening and simultaneous quantification of nicotine and alkaloid impurities in
Sophia Barhdadi1, Bart Desmedt2, Patricia Courselle2
1Medicines and health products, Scientific Direction of Chemical and Physical Health Risks, Sciensano, Rue Juliette Wytsmanstraat 14, 1050 Brussels, Belgium; Department of In Vitro Toxicology and Dermato-Cosmetology (IVTD), Vrije Universiteit Brussel (VUB), Laarbeeklaan 103, B-1090 Brussels, Belgium.
Abstract:
The electronic cigarette (e-cigarette) has emerged as a popular alternative to the traditional hazardous tobacco cigarette. The substantial increase in e-cigarette use also urgently calls for controlling the quality of e-cigarette refill liquid products (e-liquids). Currently, the most important quality indicator of e-liquid products is the quantification of nicotine and its related impurities. Although different methods have been published to measure nicotine and impurity levels, the majority of them use a targeted LC-MS/MS approach. There is, however, a need for more robust quantification methods that are easy to implement in most control (industrial and governmental) laboratories. Therefore, in this study, a simple dilute-and-shoot UHPLC-DAD method has been developed and validated for the simultaneous quantification of nicotine and its alkaloid impurities in electronic cigarette refills. An optimal separation of the alkaloids was achieved in a runtime of 11 min. The method was successfully validated using the "total error" approach in accordance with the validation requirements of ISO-17025. During this validation, interference between the target components and a number of popular flavouring compounds such as vanillin, maltol, ethylacetate, etc. could be excluded. In addition, small changes to the column temperature, pH and molar concentration of the mobile phase buffer were deliberately introduced in order to assess the robustness of the method. Only a slightly different outcome between the newly developed UV-detection method and the targeted MS approach was found, due to the sensitivity of the different detection techniques. However, in the context of quality control of nicotine related impurities, for which the European Pharmacopoeia limits are currently applied, the sensitivity of the UHPLC-DAD method was found to be within the acceptable range. Despite the somewhat lower selectivity of the newly developed UV-detection technique versus a targeted LC-MS/MS approach, it may be concluded that this method is a suitable alternative for quality control purposes.
More Related Videos
10:44Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System
Published on: May 24, 2017
08:39Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
Published on: August 25, 2018
Related Concept Videos
Primary and Secondary Growth in Roots and Shoots
Cholinergic Receptors: Nicotinic
There are two types of nicotinic receptors: neuromuscular (NM/NM/N1) and neuronal (NN/NN/N2). The two families differ based on their location and selectivity to...
Solution Concentration and Dilution
CNS Depressants: Alcohol and Nicotine
Formation of Dilute Urine
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...