Magnetic Resonance Elastography in Primary Sclerosing Cholangitis: Interobserver Agreement for Liver Stiffness
Safa Hoodeshenas1, Christopher L Welle1, Patrick J Navin1
1Department of Radiology, Mayo Clinic College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905.
Rationale And Objective:
Primary sclerosing cholangitis, a chronic liver disease causes heterogeneous parenchymal changes and fibrosis. Liver stiffness measurement (LSM) with magnetic resonance Elastography (MRE) may be affected by this heterogeneous distribution. We evaluated interobserver agreement of LSM in primary sclerosing cholangitis (PSC) with manual and automated methods to study the influence of heterogeneous changes.
Materials And Methods:
A total of 79 consecutive patients with PSC who had a liver MRI and MRE formed the study group. Three readers with 1-3 years' experience in MRE and a MRE expert (11 years' experience) independently performed LSM. Each reader manually drew free hand (fROI) and average (aROI) on stiffness maps. Automatic liver elasticity calculation (ALEC) was used to generate automated LSM. The expert fROI was the reference standard. Correlation analysis and absolute intra-class correlation coefficient (ICC) analysis was performed.
Results:
LSM data of 79 livers and 315 sections were evaluated. There was excellent ICC between expert and reader fROIs (0.989, 95% confidence interval, and 0.985-0.993) and aROIs (0.971, 95% confidence interval, and 0.953-0.983) and ALEC (0.972, 0.957-0.982) with fROI performing better. The areas measured with fROIs and ALEC had moderate ICC with Expert fROI (0.64 and 0.56, respectively) whereas aROI area had a poor ICC of 0.12. Comparison of multiple methods showed significant differences in LSM between expert fROI and aROI of two readers and no significant differences for fROIs of all three readers.
Conclusion:
LSM with MRE in PSC patients shows excellent interobserver agreement with both fROI and aROI methods with better performance with fROI. fROI may therefore be preferred for LSM measurements in PSC.
More Related Videos
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Resonance
Imaging Studies IV: Magnetic Resonance Imaging
Measurement of Bioavailability: Pharmacokinetic Methods