Related Experiment Video
Updated: Jan 27, 2026

06:09
Optic Nerve Sheath Point of Care Ultrasound: Image Acquisition
Published on: August 18, 2023
2.8K
Optic nerve sheath diameter measurement in hypoxic ischaemic brain injury after cardiac arrest
Nicola Rosa1, Livio Vitiello1, Maddalena De Bernardo1
1Department of Medicine, Surgery and Dentistry, "Scuola Medica Salernitana", University of Salerno, Salerno, Italy.
Resuscitation
|March 18, 2019
Abstract
No abstract available in PubMed .
Related Concept Videos
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
357
Assessing safety in wind-exposed installations is crucial to preventing potential failures. This example explores the calculation and design adjustments needed to mount a circular disc on a building facade, where wind forces are a primary concern. A 4-meter diameter disc was initially designed as an aesthetic feature facing winds at a velocity of 25 meters per second, with an air density of 1.25 kilograms per cubic meter. Given these conditions, the drag force on the disc was determined using...
357
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
3.3K
Cardiac output (CO), the amount of blood the heart pumps per minute, is a parameter in cardiovascular physiology determined by stroke volume and heart rate. Stroke volume, the amount of blood pushed from one of the ventricles per heartbeat, is influenced by preload, afterload, and contractility.
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
3.3K
Cardiac Output I:Effect of Heart Rate on Cardiac Output
2.5K
Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
2.5K
Cardiac Cycle
12.7K
The cardiac cycle refers to the sequence of events that occur in the heart from the beginning of one heartbeat to the next. It's characterized by alternating periods of contraction (systole) and relaxation (diastole) of the heart muscles.
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
12.7K
The Cardiac Cycle
98.0K
The heart beats rhythmically in a sequence called the cardiac cycle—a rapid coordination of contraction (systole) and relaxation (diastole).
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
98.0K
Nerve Supply of the GI Tract
3.5K
The neuronal supply to the gastrointestinal (GI) tract is essential for regulating various functions, including digestion, absorption, and movement of food. This intricate network of nerves is known as the enteric nervous system (ENS), often referred to as the "second brain" of the body.
The enteric nervous system consists of two major plexuses: the myenteric plexus (Auerbach's plexus) and the submucosal plexus (Meissner's plexus). These plexuses are located within the layers of...
The enteric nervous system consists of two major plexuses: the myenteric plexus (Auerbach's plexus) and the submucosal plexus (Meissner's plexus). These plexuses are located within the layers of...
3.5K

