Related Experiment Video
Updated: Jan 27, 2026

Modeling Brain Metastases Through Intracranial Injection and Magnetic Resonance Imaging
Published on: June 7, 2020
Results of Phosphorus Magnetic Resonance Spectroscopy for Brain Metastases Correlate with Histopathologic Results
Johannes Kerschbaumer1, Daniel Pinggera1, Ruth Steiger2
1Department of Neurosurgery, Medical University of Innsbruck, Innsbruck, Austria.
Background:
Brain metastases (BMs) are classically well-circumscribed lesions. Still, the amount of edema in these neoplasms suggests either mechanisms of infiltration or defense. A better understanding of the mechanisms within the edema of BMs seems reasonable to preoperatively identify areas of potential infiltration and resect them. BMs represent tumors with high energy demand and cell turnover; therefore, they qualify for preoperative investigation with phosphorus-31 magnetic resonance spectroscopy (31PMRS), which reveals information about those characteristics.
Methods:
Ten patients with BMs were included in this trial. All underwent preoperative standard magnetic resonance imaging with additional 31PMRS. In all patients, 1 voxel within the contrast-enhancing tumor (CE+), 1 voxel at the border (including CE+ areas and surrounding T2-hyperintensive [T2+] areas), and 1 distant voxel purely including T2+ areas were determined by a neuroradiologist and a neurosurgeon. A frameless stereotactic biopsy was performed after craniotomy. Subsequently, the metabolites of the 31PMRS were analyzed and compared with the histopathologic results.
Results:
Ratios, reflecting resynthesis (CE+/border/T2+: 1.109 ± 0.192/1.112 ± 0.158/1.083 ± 0.097), hydrolysis (0.303 ± 0.089/0.360 ± 0.122/0.321 ± 0.089), energy demand (4.227 ± 2.35/3.453 ± 1.284/3.599 ± 0.833), and membrane turnover (1.239 ± 0.2611/3.453 ± 1.284/3.599 ± 0.283) were calculated and compared intraindividually with a voxel from the contralateral side (resynthesis/hydrolysis/energy demand/membrane turnover: 1.063 ± 0.085/0.335 ± 0.073/3.317 ± 0.7573/0.784 ± 0.186), respectively. Resynthesis showed a trend toward higher ratios in CE+ and border biopsies without reaching statistical significances. This trend was also seen concerning energy demand. Membrane turnover was significantly higher in CE+, border zone, and also in the T2+ areas compared with controls (P > 0.001).
Conclusions:
31PMRS in BMs provides information on metabolic changes in tumor and surrounding edema. There is proof of enhanced metabolism in tissue without histologic tumor manifestation.
More Related Videos
09:01Metabolomic Analysis of Rat Brain by High Resolution Nuclear Magnetic Resonance Spectroscopy of Tissue Extracts
Published on: September 21, 2014
09:40Phosphorus-31 Magnetic Resonance Spectroscopy: A Tool for Measuring In Vivo Mitochondrial Oxidative Phosphorylation Capacity in Human Skeletal Muscle
Published on: January 19, 2017
Related Concept Videos
Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
2D NMR: Homonuclear Correlation Spectroscopy (COSY)
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Correlations
The Phosphorus Cycle