Related Experiment Video
Updated: Jan 27, 2026

Measurements of Local Instantaneous Convective Heat Transfer in a Pipe - Single and Two-phase Flow
Published on: April 30, 2018
Tiny Pipes: 67 Cases of Flow Diversion for Aneurysms in Distal Vessels Measuring Less Than 2.0 mm
Matthew T Bender1, David A Zarrin1, Jessica K Campos1
1Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
Background:
Flow diversion is increasingly used for off-label treatments of distal circulation aneurysms. Reports of use in sub-2.0-mm vessels are scant.
Methods:
A prospectively collected, institutional review board-approved cerebral aneurysm database was reviewed to identify patients who underwent flow diversion with a 2.5-mm diameter Pipeline embolization device.
Results:
Sixty-seven aneurysms were treated in 67 procedures (66 [99%] successful, 64 [96%] single device, 2 [3%] with 2 devices) in 57 patients. Average age was 56 years and 60% were female. Aneurysm location was 51 (76%) anterior cerebral artery, 14 (21%) middle cerebral artery, and 2 (3%) posterior cerebral artery. Aneurysm size was 4.1 ± 3.0 mm (1-20 mm). Safety outcomes included 3 major strokes (4.5%) resulting in permanent neurologic deficit (modified Rankin Scale score 6,4,4), including 1 mortality (1.5%). Acute stent thrombosis was observed intraprocedurally or within 24 hours of each stroke. There were 2 small-volume (<10 cm3, 40 cm3) dependent intracerebral hemorrhage (3.0%) that resolved without permanent neurologic deficit. For effectiveness, 71% of patients underwent follow-up angiography. Complete occlusion was achieved by 88% at 6 months, 86% at 12 months, and 89% at last follow-up. A slight vessel diameter reduction was apparent on average 6.9 months after the procedure, which was statistically significant at the proximal (P = 0.001) but not distal (P = 0.317) device end. Preoperative average parent vessel diameter was 1.9 mm proximally (range, 1.1-2.6 mm) and 1.7 mm distally (range, 1.0-2.3 mm) of the Pipeline embolization device. Follow-up average vessel diameter was 1.7 mm proximally (range, 0.7-2.4 mm) and 1.6 mm distally (range, 0.6-2.1 mm). Flow delay associated with vessel diameter reduction occurred once. There were no cases of asymptomatic vessel occlusion.
Conclusions:
Flow diversion can be safe and effective for aneurysms originating from vessels <2.0 mm in diameter. Heightened vigilance for the prevention and management of acute stent and vessel thrombosis is warranted in these cases.
Related Concept Videos
General Characteristics of Pipe Flow I
The classification of fluid...
General Characteristics of Pipe Flow II
The distance to reach a fully developed flow is called the entrance length and depends on the...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Pipe Flowrate Measurement: Problem Solving
Design Example: Flow of Oil Through Circular Pipes
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...

