Related Experiment Video
Updated: Jan 27, 2026

A Novel Murine Model of Arteriovenous Fistula Failure: The Surgical Procedure in Detail
Published on: February 3, 2016
Surgical resection of carotid-jugular arteriovenous fistula after multiple failed embolisation
Luen Shaun Chew1, Julian Xinguang Han1, Yew Poh Ng1
1Department of Neurosurgery, National Neuroscience Institute, Singapore, Singapore.
Abstract:
Carotid-jugular fistula is a rare presentation of arteriovenous fistula. A case of a 60-year-old Chinese man who presented with iatrogenic carotid-jugular fistula with multiple fistulous points was reported. His presenting complaint was a gradually enlarging right pulsatile neck mass complicated by worsening symptoms of congestive cardiac failure. He had recent mitral valve annuloplasty, and a right internal jugular central venous pressure monitor insertion was performed then. Angiography revealed right carotid-jugular fistula with feeders from the external carotid, internal carotid and right vertebral arteries, all draining into the right internal jugular vein. He underwent embolisation twice resulting in transient improvement in clinical symptoms, and surgical resection was later performed in view of residual arteriovenous shunting and gradual clinical deterioration. Following surgery, he was discharged and resumed work as a janitor with no recurrent symptoms for 3 years now. In this report to be added into the literature, we discuss a rare case of iatrogenic carotid-jugular fistula with multiple fistulous points which required embolisation and subsequently surgical resection.
Related Concept Videos
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Multiple Allele Traits
Multiple Regression
Farmers can use multiple regression to determine the crop yield based on more than one factor, such as water availability, fertilizer, soil properties, etc. Here, the crop yield is the response or dependent variable as it depends on the other independent variables. The analysis requires the construction of a scatter plot...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Multiple Voltage Sources
In series, the positive terminal of one battery is connected to the negative terminal of another battery. Hence, the voltage of each battery is added to give the net voltage, which is increased because each battery boosts the electrons that enter it. The same current flows through each battery because they are connected in series.
Batteries are...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...

