Related Experiment Video
Updated: Jan 27, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Intramedullary screw fixation for simple displaced olecranon fractures
Willem-Maarten P F Bosman1,2, Benjamin L Emmink3,4, Abhiram R Bhashyam4,5,6
1Department of Surgery, St Antonius Hospital, Utrecht, The Netherlands. w.m.bosman@asz.nl.
Purpose:
Olecranon fractures are common and typically require surgical fixation due to displacement generated by the pull of the triceps muscle. The most common techniques for repairing olecranon fractures are tension-band wiring or plate fixation, but these methods are associated with high rates of implant-related soft-tissue irritation. Another treatment option is fixation with an intramedullary screw, but less is known about surgical results using this strategy. Thus, the purpose of this study was to report the clinical and functional outcomes of olecranon fractures treated with an intramedullary cannulated screw.
Methods:
We identified 15 patients (average age at index procedure 44 years, range 16-83) with a Mayo type I or IIA olecranon fracture who were treated with an intramedullary cannulated screw at a single level 2 trauma center between 2012 and 2017. The medical record was reviewed to assess radiographic union, postoperative range of motion and complications (including hardware removal). Patient-reported outcome was evaluated using the Disabilities of the Arm, Shoulder and Hand (DASH) score. Average follow-up was 22 months (range 8-36 months).
Results:
By the 6th month post-operative visit, 14 patients had complete union of their fracture and 1 patient had an asymptomatic non-union that did not require further intervention. Average flexion was 145° (range 135-160) and the average extension lag was 11° (range 0-30). Implants were removed in 5 patients due to soft-tissue irritation. Average DASH score (± standard deviation) by final follow-up was 16 ± 10.
Conclusions:
Fixation of simple olecranon fractures with an intramedullary screw is a safe and easy fixation method in young patients, leading to good functional and radiological results. Compared to available data, less hardware removal is necessary than with tension-band wiring or plate fixation.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Position and Displacement
Displacement Current
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Position and Displacement Vectors
Further, several important kinds of...