High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Is Single-Photon Emission Computed Tomography/Computed Tomography Superior to Single-Photon Emission Computed
1Attending Physician, Department of Nuclear Medicine, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Purpose:
Single-photon emission computed tomography (SPECT) with technetium-99m diphosphates plays an important role in assessing unilateral condylar hyperplasia (UCH). The aim of this study was to evaluate whether quantification methods of SPECT plus CT (SPECT/CT) based on precise region-of-interest (ROI) drawings made under the guide of CT images were more accurate than conventional SPECT methods in the assessment of UCH growth.
Materials And Methods:
This study is a nonblinded retrospective case series. Patients with UCH who had undergone SPECT/CT were enrolled. CT images were used to guide ROI drawings around the anatomic contour of the affected and contralateral condyles on SPECT/CT images versus fixed ROIs on conventional SPECT images. Mean and maximum values within the ROIs were recorded to compute percentile ratios. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and receiver operating characteristic (ROC) curves were calculated separately for SPECT-based methods (SPECTaver, SPECTmax) and SPECT/CT methods (SPECTCTaver, SPECTCTmax). The area under the ROC curve of each method was calculated and compared pairwise.
Results:
Fifty-six patients (30 patients with progressive and 26 patients with nonprogressive mandibular asymmetry) were evaluated. SPECTmax had the highest sensitivity of 83.3%, followed by SPECTCTmax, SPECTaver, and SPECTCTaver. In contrast, SPECTaver, SPECTCTmax, and SPECTmax had similar specificities, PPVs, and NPVs. Nonetheless, SPECTCTaver had the lowest specificity, PPV, and NPV among all methods. ROC analysis also showed similar diagnostic performances among SPECTaver, SPECTmax, and SPECTCTmax (P > .05) and poorer diagnostic performance of SPECTCTaver compared with the other 3 methods (P < .05).
Conclusions:
The method of using ROIs drawn around the contour of the condyle on SPECT/CT images does not show improved accuracy over conventional SPECT-fixed ROI methods in assessing UCH.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Emission Spectra
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...