Antimicrobial Synergy Testing by the Inkjet Printer-assisted Automated Checkerboard Array and the Manual Time-kill Method
Published on: April 18, 2019
Where should antibiotic gradient diffusion strips be crossed to assess synergy? A comparison of the standard method
Ana Motos1, Lindsay M Avery2, Kailynn J DeRonde3
1Center for Anti-Infective Research and Development, Hartford Hospital, Hartford, CT, USA; Division of Animal Experimentation, Department of Pulmonary and Critical Care Medicine, Hospital Clinic, Barcelona, Spain.
Abstract:
Multi-drug resistance among Pseudomonas aeruginosa in hospitals, and particularly intensive care units, has achieved alarming rates. Some combination antimicrobial therapies have demonstrated promising synergistic effects and an ability to overcome resistance without increasing drug-related toxicities. Nevertheless, rapid and feasible methods to identify synergy have not been routinely implemented in clinical microbiology laboratories. Synergistic activity of meropenem plus tobramycin or levofloxacin against clinical P. aeruginosa isolates (N=21) was assessed by two different methods using gradient diffusion strips (GDSs). A 90° angle was created at the intersection of the minimum inhibitory concentration (MIC) of each drug by the standard method, and by a novel method, the cross was placed at clinically relevant steady-state concentrations (Css) based on recommended dosing regimens. Fractional inhibitory concentration indexes were determined to describe antibiotic interactions. Time-kill analyses were performed over 24 h in duplicate for instances of discordance between the standard cross method and the novel method. Synergy between meropenem and tobramycin by the novel method was observed in one (4.8%) isolate and between meropenem and levofloxacin in two (9.5%) isolates. Agreement with the standard method was 86-100% for meropenem plus tobramycin and meropenem plus levofloxacin combinations, respectively. Time-kill studies resulted in agreement with GDSs crossed at Css in two of three instances of discordance between GDS methods. This novel method of synergy testing that involves crossing GDSs at steady-state concentrations may be a rapid and feasible tool for routine practice. Further comparisons of this novel procedure with time-kill methods are needed.
Related Concept Videos
Steady State Concentration
Most drugs are administered in repeated doses at fixed intervals or through continuous...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Diffusion
Empirical Method to Interpret Standard Deviation
This rule is used widely in statistics to calculate the proportion of data values...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...