Related Experiment Video
Updated: Jan 27, 2026

Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer
Published on: February 12, 2022
Sequential simulation computed tomography allows assessment of internal rectal movements during preoperative
Dae Sik Yang1, Jung Ae Lee1, Won Sup Yoon2
1Department of Radiation Oncology, Guro Hospital, Korea University College of Medicine, Ansan, Korea.
Purposes:
The purpose of this study was to assess the internal rectal movement and to determine the factors related to extensive internal rectal movement using sequential simulation computed tomography (CT) images.
Materials And Methods:
From 2010 to 2015, 96 patients receiving long-course preoperative chemoradiotherapy were included in our retrospective study. The initial simulation CT (Isim-CT) and follow-up simulation CT (Fsim-CT) for a boost were registered according to the isocenters and bony structure. The rectums on Isim-CT and Fsim-CT were compared on four different axial planes as follows: (1) lower pubis symphysis (AXVERYLOW), (2) upper pubis symphysis (AXLOW), (3) superior rectum (AXHIGH), and (4) middle of AXLOW and AXHIGH (AXMID). The involved rectum in the planning target volume was evaluated. The maximal radial distances (MRD), the necessary radius from the end of Isim-CT rectum to cover entire Fsim-CT rectum, and the common area rate (CAR) of the rectum (CAR, (Isim-CT∩Fsim-CT)/(Isim-CT)) were measured. Linear regression tests for the MRDs and logistic regression tests for the CARs were conducted.
Results:
The mean ± standard deviation (mm) of MRDs and CAR <80% for AXVERYLOW, AXLOW, AXMID, and AXHIGH were 2.3 ± 2.5 and 8.9%, 3.0 ± 3.7 and 17.4%, 4.0 ± 5.2 and 27.1%, and 4.1 ± 5.2 and 25%, respectively. For MRDs and CARs, a higher axial level (AXVERYLOW/AXMID-HIGH, P = 0.018 and P = 0.034, respectively), larger bladder volume (P = 0.054 and P = 0.017, respectively), smaller bowel gas extent (small/marked, P = 0.014 and P = 0.001, respectively), and increased bowel gas change (decrease/increase, both P < 0.001) in rectum were associated with extensive internal rectal movement in multivariate analyses.
Conclusions:
As a result of following internal rectal movement through sequential simulation CT, the rectum above the pubis symphysis needs a larger margin, and bladder volume and bowel gas should be closely observed.
More Related Videos
05:45Diagnosis of Hirschsprung's Disease by Immunostaining Rectal Suction Biopsies for Calretinin, S100 Protein and Protein Gene Product 9.5
Published on: April 26, 2019
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Internal Energy
Internal Energy
Internal Receptors