Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial
Ashish Agrawal1, Roger Cheng2, Julin Tang1
1Department of Anesthesia and Perioperative Care, University of California, San Francisco, CA.
Objectives:
Intracranial pressure over 20 mm Hg is associated with poor neurologic prognosis, but measuring intracranial pressure directly requires an invasive procedure. Dilation of the optic nerve sheath on axial ultrasound of the eye has been correlated with elevated intracranial pressure, but optimal cutoffs have been inconsistent possibly related to the measurement technique. A coronal technique has been studied on healthy volunteers but not on patients with high intracranial pressure. We compared two measurement techniques (axial and coronal) in patients with suspected high intracranial pressure due to trauma, bleeding, tumor, or infection.
Design:
Prospective blinded observational study.
Setting:
Two tertiary referral center ICUs.
Patients:
Twenty adults admitted to the ICU at risk for increased intracranial pressure expected to receive invasive intracranial monitoring.
Interventions:
Ultrasound measurements of the optic nerve sheath in axial and coronal views either averaged between eyes or the highest in either eye.
Measurements And Main Results:
Coronal measurements showed less variability between each eye than axial measurements (mean difference 0.5 mm vs 1 mm; p = 0.03) and were associated with high intracranial pressure at first measurement and over 24 hours (area under the receiver operating characteristic range 0.7-0.8). Mean and highest axial measurements showed improved association with first (area under the receiver operating characteristic 0.87-0.94) and highest intracranial pressure measurement (area under the receiver operating characteristic 0.89-0.96) within 24 hours. A cutoff of highest axial measurement in either eye greater than 6.2 mm or mean axial measurement between eyes of 5.6 mm had a sensitivity of 100% in predicting high intracranial pressure over the following 24 hours.
Conclusions:
The highest axial measurement of optic nerve sheath diameter in either eye is the most predictive of patients with high intracranial pressure in our population. This comparison of measurement techniques has not previously been described and should be further explored to set test cutoffs for ultrasound of the optic nerve sheath diameter.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
The Sense of Self: Reflected Self-Appraisal and Social Comparison