Morphometric Protocol for the Objective Assessment of Blastocyst Behavior During Vitrification and Warming Steps

Marjan Taborin1, Borut Kovačič2

  • 1Department of Reproductive Medicine and Gynecological Endocrinology, University Medical Centre Maribor.

Related Concept Videos

Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
1.2K
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.6K
Potential Due to a Polarized Object01:29

Potential Due to a Polarized Object

A neutral atom consists of a positively charged nucleus surrounded by a negatively charged electron cloud. When placed in an external electric field, the external electric force pulls the electrons and nucleus apart, opposite to the intrinsic attraction between the nucleus and the electrons. The opposing forces balance each other with a slight shift between the center of masses of the nucleus and the electron cloud, resulting in a polarized atom. On the other hand, a few molecules, like water,...
770
Potential Due to a Magnetized Object01:24

Potential Due to a Magnetized Object

Magnetic dipoles in magnetic materials are aligned when placed under an external magnetic field. For paramagnets and ferromagnets, dipole alignment occurs in the direction of the magnetic field. However, the dipoles align opposite to the field in the case of diamagnets. This state of magnetic polarization due to the external field is called magnetization. Magnetization is defined as the dipole moment per unit volume. It plays a similar role to polarization in electrostatics.
The vector...
792
What is Behavior?00:54

What is Behavior?

Behaviors are actions that an organism engages in—they can be related to finding food, reproducing, defending against threats, and many other possible actions. Behaviors include activities related to the environment around the animal—such as migration—as well as social interactions within a species or population. Many behaviors involve motor output—that is, muscle movements—while others involve less visible actions, such as learning.
10.3K
Rate-Determining Steps03:08

Rate-Determining Steps

Relating Reaction Mechanisms
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
37.0K