Related Experiment Video
Updated: Jan 27, 2026

Nondestructive Monitoring of Degradable Scaffold-Based Tissue-Engineered Blood Vessel Development Using Optical Coherence Tomography
Published on: October 3, 2018
Routine use of optical coherence tomography in bioresorbable vascular scaffold implantation: insights on technique
Hesham K Abdelaziz1,2, Hossamaldin Z Abuomara1,2, Montasir H Ali1
1Department of Cardiovascular Medicine, Lancashire Cardiac Center, Blackpool Victoria Hospital, Blackpool, UK.
Background:
Data from prior studies have shown increased risk of adverse outcomes with bioresorbable vascular scaffolds (BVS) compared with drug-eluting stents.
Objective:
The objective of this study was to study the long-term outcomes with routine use of optical coherence tomography (OCT) for optimization of BVS implantation.
Patients And Methods:
Clinical, procedural, and outcome data were collected for all patients who received ABSORB BVS between February 2014 and March 2016 in our tertiary center (n=86). Preimplantation and postimplantation OCT was performed in all cases. Outcomes of interest included acute device success and long-term clinical outcomes including cardiac mortality, target vessel myocardial infarction, ischemia-driven target lesion revascularization, and scaffold thrombosis.
Results:
A total of 86 patients were included (106 lesions, 115 BVS implanted). Mean age was 59.5±10.9 years, with 66% men. Mean lesion length was 25.2±15.6 mm and mean reference vessel diameter was 3.42±0.45 mm. Type B2/C accounted for 40% of the lesions. All scaffold implantations followed the predilation, proper sizing, and postdilation strategy. Of the 115 scaffolds analyzed, 11 (9.5%) required further intervention based on prespecified OCT endpoints. On multivariate regression analysis, complex coronary lesion (type B2/C) was the single independent predictor of OCT use in scaffold optimization (odds ratio=6.3, 95% confidence interval: 1.3-7.8, P=0.02). At a mean follow-up duration of 31±7.1 months, no cases of cardiac mortality, target vessel myocardial infarction, ischemia-driven target lesion revascularization, or scaffold thrombosis were reported.
Conclusion:
Operators may consider OCT use for optimization of BVS implantation particularly in patients with complex coronary lesions.
Related Concept Videos
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Long-term Depression
Long-term Depression
Calcium Ion Concentration Mechanism
If over...
Seedless Vascular Plants
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...