The shufflon of IncI1 plasmids is rearranged constantly during different growth conditions

Michael S M Brouwer1, Stephanie D Jurburg2, Frank Harders2

  • 1Department of Bacteriology and Epidemiology, Wageningen Bioveterinary Research, Lelystad, The Netherlands.

Plasmid
|March 20, 2019
PubMed

Related Concept Videos

EDTA: Conditional Formation Constant01:09

EDTA: Conditional Formation Constant

Each EDTA molecule has six binding sites: four carboxyl groups and two amino groups. The fully protonated form of EDTA is represented as H6Y2+. However, it can exist in different forms, H5Y+, H4Y, H3Y−, H2Y2−, and HY3−, depending on the pH of the solution. In very basic solutions with pH > 10.17, the fully deprotonated form, Y4−, is the predominant species that readily complexes with metal ions in a 1:1 ratio.
For the equilibrium reaction of the metal with the...
2.1K
The Equilibrium Binding Constant and Binding Strength02:18

The Equilibrium Binding Constant and Binding Strength

The equilibrium binding constant (Kb) quantifies the strength of a protein-ligand interaction. Kb can be calculated as follows when the reaction is at equilibrium:
15.0K
[3,3] Sigmatropic Rearrangement of 1,5-Dienes: Cope Rearrangement01:21

[3,3] Sigmatropic Rearrangement of 1,5-Dienes: Cope Rearrangement

The Cope rearrangement is classified as a [3,3] sigmatropic shift in 1,5-dienes, leading to a more stable, isomeric 1,5-diene. The reaction involves a concerted movement of six electrons, four from two π bonds and two from a σ bond, via an energetically favorable chair-like transition state.
3.4K
Constant Pressure Calorimetry03:02

Constant Pressure Calorimetry

Calorimetry is a technique used to measure the amount of heat involved in a chemical or physical process or to measure the heat transferred to or from a substance. The heat is exchanged with a calibrated and insulated device called the calorimeter. Calorimetry experiments are based on the assumption that there is no heat exchange between the insulated calorimeter and the external environment. The well-insulated calorimeters prevent the transfer of heat between the calorimeter and its external...
97.6K
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.7K
[3,3] Sigmatropic Rearrangement of Allyl Vinyl Ethers: Claisen Rearrangement01:24

[3,3] Sigmatropic Rearrangement of Allyl Vinyl Ethers: Claisen Rearrangement

The Claisen rearrangement is a [3,3] sigmatropic rearrangement of allyl vinyl ethers to unsaturated carbonyl compounds. The rearrangement is a concerted pericyclic reaction proceeding via a chair-like transition state.
2.8K