Related Experiment Video
Updated: Jan 27, 2026

Brain Morphology of Cannabis Users With or Without Psychosis: A Pilot MRI Study
Published on: August 18, 2020
Variation in use and outcomes related to midline catheters: results from a multicentre pilot study
Vineet Chopra1,2,3, Scott Kaatz4, Lakshmi Swaminathan5
1The Division of Hospital Medicine, Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, Michigan, USA vineetc@umich.edu.
Background:
While midline vascular catheters are gaining popularity in clinical practice, patterns of use and outcomes related to these devices are not well known.
Methods:
Trained abstractors collected data from medical records of hospitalised patients who received midline catheters in 12 hospitals. Device characteristics, patterns of use and outcomes were assessed at device removal or at 30 days. Rates of major (upper-extremity deep vein thrombosis [DVT], bloodstream infection [BSI] and catheter occlusion) and minor complications were assessed. χ2 tests were used to examine differences in rates of complication by number of lumens, reasons for catheter removal l, and hospital-level differences in rates of midline use.
Results:
Complete data on 1161 midlines representing 5%-72% of all midlines placed in participating hospitals between 1 January 2017 and 1 March 2018 were available. Most (70.8%) midlines were placed in general ward settings for difficult intravenous access (61.4%). The median dwell time of midlines across hospitals was 6 days; almost half (49%) were removed within 5 days of insertion. A major or minor complication occurred in 10.3% of midlines, with minor complications such as dislodgement, leaking and infiltration accounting for 71% of all adverse events. While rates of major complications including occlusion, upper-extremity DVT and BSI were low (2.2%, 1.4% and 0.3%, respectively), they were just as likely to lead to midline removal as minor complications (53.8% vs 52.5%, p=0.90). Across hospitals, absolute volume of midlines placed varied from 100 to 1837 devices, with corresponding utilisation rates of 0.97%-12.92% (p<0.001).
Conclusion:
Midline use and outcomes vary widely across hospitals. Although rates of major complications are low, device removal as a result of adverse events is common.
Related Concept Videos
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Pilot and Numeric Relaying
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...